Linked alarms all sound when one does. If there's no smoke, one faulty or badly placed alarm, or the link between them, is usually the cause. We find it, and replace the problem alarm or fix the link.

5.0 from 24 Google reviewsUpfront pricesLicensed & insured

Photoelectric smoke and carbon monoxide alarm

Offers on this job

  • $0Call-out feeOn booked jobs, Monday to Friday, 7am to 5pm.
  • $139Home safety inspectionSwitchboard, safety switches, smoke alarms and wiring, all checked.
  • $60 offYour first jobNew customers save on their first booked job.

The $0 call-out is for booked jobs: a time we have set together, with the work going ahead. It applies Monday to Friday, 7am to 5pm. After-hours emergency call-outs have a minimum charge of $349 + GST, and Lachie confirms it on the phone before he drives out.

How one alarm sets off the whole house

Linked alarms sound together so you hear a fire wherever it starts. One problem alarm does the same.

A floor plan showing why smoke alarms beep and where they should goA single-storey floor plan with two bedrooms, a bathroom, a hallway, a living room and a kitchen. A hallway alarm outside the bedrooms is chirping, an old alarm in the living room is past its date, dashed lines link the alarms together, and an alarm right beside the kitchen is set off by steam. BedroomBedroomBath KitchenLivingDiningHall 2012 12345
What the numbers show
  1. A chirp, or the full alarm?
  2. More than 10 years old
  3. Outside the bedrooms
  4. Linked together
  5. Too close to the kitchen or bathroom
What you're looking at: A floor plan of a typical house seen from above. The alarm in the hallway is chirping, the one in the living room is past its use-by year, dashed lines show the alarms linked together, and the alarm next to the kitchen is being set off by cooking steam.Simplified drawing. Red shows the fault or a switch that has tripped. Every property is different: Lachie will show you what's going on at yours.
  1. A chirp, or the full alarm?

    A chirp every minute or so is a battery or end-of-life warning, usually from one alarm. A full alarm from every alarm means one set off the rest.

  2. More than 10 years old

    An ageing alarm can start going off on its own, and in a linked set it takes the others with it. The date is on the back or side.

  3. Outside the bedrooms

    Every level needs at least one working alarm, ideally here. Linking means this alarm sounds too, wherever the smoke is.

  4. Linked together

    By a cable between alarms or a wireless signal. When one senses smoke, real or not, every alarm sounds. A fault in the link can do the same.

  5. Too close to the kitchen or bathroom

    The most common starter. Toast or shower steam reaches one alarm, and the whole house goes off.

What usually sets them all off: more detail on each cause

Linked alarms pass on whatever one alarm senses. So the cause is nearly always in one alarm, or in the link between them.

  • Steam or cooking reaching one alarm Most common

    An alarm right outside the bathroom or beside the kitchen reacts to steam and cooking smoke, and the link sets off the rest. Moving that alarm usually fixes the whole system.

  • One alarm past its 10 years Check the date

    Manufacturers say to replace smoke alarms every 10 years. An ageing sensor can go off on its own, and in a linked set every alarm follows it.

  • Dust or an insect in one sensor

    Renovation dust, or a small insect inside one alarm's sensor, looks like smoke to that alarm. It sounds, and so does every other alarm.

  • Mixed or mismatched alarms

    Linked alarms usually need to be the same brand or system. A different alarm added to an old set can cause false alarms.

  • A fault in the link wiring Hardwired alarms

    Hardwired alarms are often linked by a cable through the ceiling. If it's damaged during building work or loose at one alarm, the system can sound for no reason.

  • Smoke from outside Less common

    A wood heater, a neighbour's fire or a hazard reduction burn can drift in through an open window to one alarm, and set off the rest.

Is it one alarm setting off the rest?

Look and listen while it happens. The details tell us which alarm to look at.

  • One alarm has a different light

    On many linked alarms, the one that started it flashes differently from the rest. Check the model's manual for what each light means.

  • It starts when you cook or shower

    The alarm nearest the kitchen or bathroom is picking up steam or smoke and setting off the others.

  • It happens at random, with no smoke

    Think of an ageing alarm, dust or an insect in one sensor, or a fault on the link wiring.

  • It started after work on the house

    Mismatched new alarms, a link cable damaged during building work, or sanding dust can all set off a linked system.

  • They start again after you hush them

    If they go off again a few minutes later with no smoke, the starting alarm is still sensing something, or it has failed.

How we find the alarm that starts it

We find the alarm, or the part of the link, that's causing it, then replace that alarm, fix the link wiring or replace the set.

  1. 1

    Talk it through on the phone

    Lachie asks when it happens and whether one alarm's light looks different. If it sounds like more than a false alarm, he'll tell you what to do first.

  2. 2

    Test each alarm and read its date

    We test every alarm, check its age and type, and note which are linked by cable and which by wireless signal. Mixed brands and ages show up here.

  3. 3

    Find the starter, then check the link

    We set off each alarm in turn to check the others respond, and test the hardwired link for faults. That shows whether it's one alarm or the wiring between them.

  4. 4

    Replace or fix the link, then test together

    We replace or move the problem alarm with a new one, fix the link wiring, or replace the set if it's due. Every alarm is tested together, and you get a Certificate of Compliance for Electrical Work (CCEW) where the work needs one.

Replace one alarm, or the whole linked set: your options side by side

It comes down to the age of your alarms and whether they still work together properly.

Replace or move the problem alarm

A linked set under 10 years old, with one alarm causing the trouble

  • The quickest fix. The new alarm is matched to the others so the link still works.
  • If the rest are near their 10 years, the next one may not be far behind.
  • About 10 years for the new alarm.

Fix the link wiring

False alarms that started after building work, with no faulty alarm found

  • Fixes the cause and keeps alarms that are still in date.
  • Tracing a damaged cable in the ceiling can take longer.
  • For good, once the link is fixed.

Replace the whole set

Alarms over 10 years old, mixed brands, or a set that keeps false-alarming

  • Every alarm new, the same system and the same age, each with a 10-year lithium backup battery.
  • A bigger job than one alarm.
  • About 10 years. Replace them together next time.

In NSW every home must have working smoke alarms, at least one on each level, and landlords must keep them in working order. Linked alarms usually only work together if they're the same brand or system, so we check what you have first. We fit all brands, can match an existing linked set, and fit wireless-linked alarms where running a cable isn't practical. Buy the alarms through us and we pass on our trade discount.

What you can safely do now

Treat it as a real fire until you've checked.

Safe to do now

  • Check every room for smoke, heat or a burning smell. If there is any, get everyone out and call 000.
  • If it's clear, find the alarm with a different light and press its test or hush button. Check the manual if you're not sure which button.
  • Open windows and fan the air near any alarm by the kitchen or bathroom.
  • Note which alarm started it, the time, and what was happening.
  • Renting? Tell your landlord or property manager in writing.

Don't

  • Don't take hardwired alarms down or pull them off their bases. They're wired to 240 volts.
  • Don't rely on switching the alarms off at the switchboard. They have backup batteries, so they usually keep sounding.
  • Don't take batteries out and leave them out, or cover alarms with tape or bags.

Call straight away if

  • Smoke or fire: get everyone out, close doors behind you and call 000. Never put water on an electrical fire.
  • The alarms keep going off with no smoke, or won't stop after you press hush.
  • An alarm smells of burning, looks scorched or has no power light.
  • You manage a rental and the alarms aren't working properly. Landlords must keep smoke alarms in working order.
Call Lachie

What locals say

5.0 from 24 Google reviewsWord for word, nothing edited.

  • We have had Lachie from Cazlec do a lot of work on our home in Merewether. He has always been honest and reliable and we know he will enjoy many years of success.

    todd blatchford, Merewether Google review

  • I've used Lachie @ Cazlec on several occasions now and highly recommend. He does a great job, is reliable, on time, and always leaves everything clean and tidy. Pricing is very fair as well.

    Doug Norton Google review

  • We have the pleasure of working with Lachie and his team at Clarke & Co Property Management for both emergency call-outs and general maintenance work. Lachie is always quick to respond, professional, and happy to help whenever needed. His communication and workmanship are consistently excellent.

    Calais Horrigan Google review

  • Cazlec (Lachlan) did a thorough and tidy job for a very reasonable price. Prompt and professional, I'll happily refer him to others. Thanks!

    Samuel Roberts Google review

  • We've been using Cazlec Electrical for our business and have always been impressed with the quality of service. They arrive when they say they will, and take the time to explain any issues and solutions clearly.

    Bobby Google review

  • Lachlan and his team have been extremely prompt when we have needed an electrician. They are professional and personable and would highly recommend them. No job too small.

    Marie Smith Google review

  • We have used Cazlec Electrical on a number of occasions and have always had a quick response and have been extremely pleased with the work they have done. I would highly recommend this company.

    Terence Coombes Google review

  • I have been using Cazlec Electrical for the last 3 years. Always on time. No hassle and gets the job done. Highly recommend.

    steven thomas Google review

  • Professional and outstanding tradesmen.

    Rob Iacopetta Google review

  • Highly recommend. Great service!

    Sharyn Rogers Google review

More reviews

Questions people ask

Why are all my smoke alarms going off at once?

They're linked, so when one alarm senses smoke, every alarm sounds. If there's no smoke, one alarm is usually picking up steam, dust or an insect, or has reached the end of its life.

How do I find which smoke alarm set off the others?

On many linked alarms, the one that started it shows a different light, such as a faster flash. The pattern varies by brand and model, so check the manual.

How do I stop all my smoke alarms going off?

Check for smoke first. If it's clear, press the hush button on the alarm that started it, and open windows near the kitchen or bathroom. To stop it happening again, the problem alarm needs replacing or the link needs fixing.

Will turning off the power stop them?

Usually not. Hardwired alarms have a backup battery, so they keep working without mains power. Don't take them down or disconnect them. They're wired to 240 volts.

Do I need to replace all my smoke alarms?

Not always. If one alarm is faulty and the rest are under 10 years old, we replace that one. If they're all past their date, or mixed brands, replacing the set makes sense. You decide.

Can you come today?

Often, yes. Lachie works Monday to Friday, 7am to 5pm, and takes urgent calls from 4am to 9:30pm, 7 days. Call 0402 079 953, tell us what the alarms are doing, and you'll get the price before any work starts.

Lachie

Get a free quote from Lachie

Four quick details and Lachie will be in touch. Your quote is back within 24 hours, with no hidden fees.

  • Free quotes. Back to you within 24 hours, in plain English, with no hidden fees.
  • Upfront pricing. You know the cost before any work starts.
  • 100% satisfaction guarantee. Not happy with the work? Lachie comes back and makes it right, free.
  • Quality guarantee. Every job done to the Australian wiring rules (AS/NZS 3000), with parts that meet Australian standards, and tested before we leave.

Rather talk it through? Call Lachie on 0402 079 953

We use your details only to quote and book this job. Privacy.