Power keeps tripping in your house? We'll find which circuit and why, and fix it

Something on one circuit is leaking power, drawing too much or shorting out. The switch that tripped tells us which. Lachie tests the circuits, finds the cause and fixes it.

5.0 from 24 Google reviewsUpfront pricesLicensed & insured

Meter box with a smart meter, a main switch and a new row of labelled safety switches, on an older black backing board with an asbestos warning sticker

Offers on this job

  • $0Call-out feeOn booked jobs, Monday to Friday, 7am to 5pm.
  • $200 offSwitchboard upgradeOld fuses or no safety switches? Save on a new switchboard.
  • $60 offYour first jobNew customers save on their first booked job.

The $0 call-out is for booked jobs: a time we have set together, with the work going ahead. It applies Monday to Friday, 7am to 5pm. After-hours emergency call-outs have a minimum charge of $349 + GST, and Lachie confirms it on the phone before he drives out.

Which switch tripped, and what tripped it

Your board has up to three kinds of switch, and each trips for a different reason. Find the one that's down and you're halfway there.

Where the fault is when your safety switch keeps trippingA switchboard with one safety switch tripped and one circuit breaker off. Its circuit runs through the house to a kettle sparking at its base, a cable in the wall with a nail through it, an outdoor light in the rain with water inside, and a power board overloaded with a heater. Switchboard Outside 12345
What the numbers show
  1. The switch that tripped
  2. A faulty appliance
  3. Water in an outdoor light or power point
  4. A damaged cable
  5. Too much on one circuit
What you're looking at: Your switchboard is on the left, with one safety switch tripped (in red). The line running from it is one circuit, and along it are the usual culprits: a kettle leaking power, a nail through a cable in the wall, an outdoor light letting in rain, and a power board with too much plugged in.Simplified drawing. Red shows the fault or a switch that has tripped. Every property is different: Lachie will show you what's going on at yours.
  1. The switch that tripped

    Wide, with a test button: a safety switch, tripped by leaking power. Narrow: a circuit breaker, tripped by overload or a short. The main switch turns off everything.

  2. A faulty appliance

    The most common cause. Worn kettles, heaters, fridges and washing machines leak power. If it trips when one thing turns on, that's the suspect.

  3. Water in an outdoor light or power point

    If it only trips in or after rain, water is getting into something outside.

  4. A damaged cable

    A nail through a cable, or rats chewing one in the roof. It can trip with nothing plugged in.

  5. Too much on one circuit

    A breaker that trips after things have run a while is overloaded. A heater, kettle and air fryer on one circuit will do it.

What usually trips the power: more detail on each cause

These are the causes we find most, roughly in order.

  • A worn or faulty appliance Most common

    Kettles, toasters, heaters, fridges and washing machines leak power to earth as their elements and motors wear, and the safety switch trips. Hardwired ones, like ovens and hot water systems, need an electrician to test them.

  • Water getting into something

    Outdoor power points with the lid open, garden and sensor lights, pool gear, and fittings under a leaking roof. It trips in or after rain, then works once things dry out.

  • Too much on one circuit

    Heaters, kettles and air fryers each draw a lot. Two or three on one circuit trips its breaker, usually after a few minutes. A new circuit fixes it for good.

  • A damaged or ageing cable

    A screw through a cable in a renovation, rats in the roof, or old insulation breaking down. We find it by testing, not by opening walls.

  • A short circuit

    When live touches neutral or earth, at a damaged cord, a burnt power point or a failed light fitting, the breaker trips instantly.

  • One safety switch for half the house Older boards

    When one safety switch covers every circuit, small leaks from many appliances add up until it trips. A safety switch per circuit fixes it.

Which switch is it? Look at the board first

Open the switchboard door and find the switch that's down or halfway. Its type tells you the kind of fault. Each has its own page, linked below.

  • A safety switch has tripped

    It's wider than the rest, with a test button marked T or Test, and often labelled RCD. It trips when power leaks to earth through a worn appliance, water or a damaged cable. One can cover several circuits.

  • A circuit breaker has tripped

    Narrow, and usually labelled with what it runs, like Lights or Kitchen power. It trips on too much load or a short. Only that circuit goes off.

  • The main switch has dropped

    Usually the largest, labelled Main Switch. If it dropped, the house drew too much at once, a big fault reached it, or the switch is failing. Get it checked today.

  • You have ceramic fuses, not switches

    Older boards have white ceramic fuses. A blown fuse works like a tripped breaker, but nothing on the board is protecting you from a shock.

  • Nothing has tripped, but some rooms are out

    Then it may not be tripping at all. A loose or burnt connection can cut part of a circuit with every switch still on.

How we find it and fix it

We test, find the fault, then fix it. We don't replace parts on a hunch.

  1. 1

    Talk it through on the phone

    Lachie asks which switch tripped, what was running and whether it was raining. A photo of your board helps. If anything sounds dangerous, he'll tell you what to switch off first.

  2. 2

    Find the circuit

    At the board, Lachie checks which circuits the tripped switch covers, then tests each one with an insulation resistance tester. That shows the faulty circuit, even one that only trips now and then.

  3. 3

    Find the cause

    On that circuit, he tests appliances one at a time, checks outdoor fittings and measures the load. A damaged cable is traced to where it's been hit.

  4. 4

    Fix it, test it, show you

    We repair or replace the faulty part, check the safety switch trips as it should, and show you what we found. If the board is part of the problem, we price it first and you decide. You get a Certificate of Compliance for Electrical Work (CCEW) where the work needs one.

Fix the fault, add a circuit, or upgrade the board: your options side by side

Most tripping is fixed by finding one faulty appliance, fitting or cable. The bigger jobs only make sense when the board or the load is the problem.

Find and fix the fault

A sound board with a fault on one circuit

  • Fixes the cause, usually in one visit.
  • A fault that only trips once a week can take longer to catch.
  • For good, once the faulty part is repaired or replaced.

Add a circuit, or split an overloaded one

A breaker that trips when the heater, kettle or air fryer is on

  • Heavy appliances get their own circuit, so they stop tripping each other.
  • New cable has to run from the board, and the board needs room for it.
  • Permanent.

Upgrade the switchboard

Old ceramic fuses, one safety switch for everything, or no room left

  • A safety switch on every circuit, so one fault no longer blacks out half the house.
  • The biggest job, with the power off while it's done. Meter or service fuse work is Ausgrid or Level 2 work.
  • Many years, built to current wiring rules, with room to add more later.

Never have a safety switch removed or bridged out, or a breaker swapped for a bigger one, to stop the tripping. Find the fault instead.

What you can safely do now

These are safe for anyone. Anything inside the switchboard, a power point or a light is licensed work.

Safe to do now

  • Open the switchboard door and find the switch that's down. Only touch it if the board is dry and undamaged.
  • Unplug things on the circuit that went off, if they're dry and safe to touch.
  • Reset the switch once. If it trips again, leave it off.
  • Note which switch it was, what was running and whether it was raining. Take a photo of the board.
  • Keep the fridge and freezer closed if they're on the circuit that's off.

Don't

  • Don't keep resetting it, hold the lever up or tape it on. Each trip is a switch cutting power to a fault.
  • Don't touch a board that's wet, scorched, buzzing or smells hot.
  • Don't take covers off power points, lights or the switchboard, or try a fix yourself. In NSW that's licensed work.
  • Don't plug an appliance you suspect into another circuit to see if it works there.

Call straight away if

  • It trips straight back off and you need the fridge, lights or medical equipment running.
  • The main switch has tripped and the whole house is out.
  • There's a burning smell, buzzing or scorch marks at the board or a power point. Switch off the main switch if it's safe to reach. If there's smoke or fire, call 000 and never put water on it.
  • You feel a tingle or shock from a tap, the shower or an appliance. Keep everyone away and call Ausgrid on 13 13 88 first.
Call Lachie

What locals say

5.0 from 24 Google reviewsWord for word, nothing edited.

  • We have had Lachie from Cazlec do a lot of work on our home in Merewether. He has always been honest and reliable and we know he will enjoy many years of success.

    todd blatchford, Merewether Google review

  • I've used Lachie @ Cazlec on several occasions now and highly recommend. He does a great job, is reliable, on time, and always leaves everything clean and tidy. Pricing is very fair as well.

    Doug Norton Google review

  • We have the pleasure of working with Lachie and his team at Clarke & Co Property Management for both emergency call-outs and general maintenance work. Lachie is always quick to respond, professional, and happy to help whenever needed. His communication and workmanship are consistently excellent.

    Calais Horrigan Google review

  • Cazlec (Lachlan) did a thorough and tidy job for a very reasonable price. Prompt and professional, I'll happily refer him to others. Thanks!

    Samuel Roberts Google review

  • We've been using Cazlec Electrical for our business and have always been impressed with the quality of service. They arrive when they say they will, and take the time to explain any issues and solutions clearly.

    Bobby Google review

  • Lachlan and his team have been extremely prompt when we have needed an electrician. They are professional and personable and would highly recommend them. No job too small.

    Marie Smith Google review

  • We have used Cazlec Electrical on a number of occasions and have always had a quick response and have been extremely pleased with the work they have done. I would highly recommend this company.

    Terence Coombes Google review

  • I have been using Cazlec Electrical for the last 3 years. Always on time. No hassle and gets the job done. Highly recommend.

    steven thomas Google review

  • Professional and outstanding tradesmen.

    Rob Iacopetta Google review

  • Highly recommend. Great service!

    Sharyn Rogers Google review

More reviews

Questions people ask

Why does my power keep tripping?

Something on one circuit is leaking power, drawing too much, or shorting. A tripped safety switch points to leakage. A tripped circuit breaker points to overload or a short. Testing the circuits tells us which, and why.

How do I know which switch tripped?

Look for the switch that's down or halfway. Safety switches are wider, with a test button marked T or Test. Circuit breakers are narrow and labelled by circuit. The main switch is usually the largest, labelled Main Switch. A photo of the board helps us on the phone.

Is it safe to keep resetting it?

No. Reset it once. If it trips again, the fault is still there, and each reset sends power back into it. Leave it off and call us.

Can too many appliances trip the power?

Yes, but they trip a circuit breaker, not the safety switch. A 2,400 watt heater or kettle draws about 10 amps, so two or three on one circuit is more than most power circuits are built for.

Do I need a new switchboard?

Usually not. Most tripping is fixed without touching the board. If yours has ceramic fuses, one safety switch for everything, no room or heat damage, Lachie will show you and price it first. The choice is yours.

Can you come today?

Often, yes. Lachie works Monday to Friday, 7am to 5pm, and takes urgent calls from 4am to 9:30pm, 7 days across Newcastle & Lake Macquarie. Call 0402 079 953.

Lachie

Get a free quote from Lachie

Four quick details and Lachie will be in touch. Your quote is back within 24 hours, with no hidden fees.

  • Free quotes. Back to you within 24 hours, in plain English, with no hidden fees.
  • Upfront pricing. You know the cost before any work starts.
  • 100% satisfaction guarantee. Not happy with the work? Lachie comes back and makes it right, free.
  • Quality guarantee. Every job done to the Australian wiring rules (AS/NZS 3000), with parts that meet Australian standards, and tested before we leave.