Available nowNewcastle, Lake Macquarie & the Hunter · Urgent calls 4am–9:30pm, 7 days

Often fixed the same day

Circuit breaker keeps tripping? We'll find what's overloading it and fix it

Usually there's too much on one circuit. Sometimes it's a short, a faulty appliance or a worn breaker. Lachie measures the load, finds the cause and fixes it.

5.0 from 24 Google reviewsUpfront pricesLicensed & insured

Meter box with a smart meter, a main switch and a new row of labelled safety switches, on an older black backing board with an asbestos warning sticker

Offers on this job

  • $0Call-out feeOn booked jobs, Monday to Friday, 7am to 5pm.
  • $200 offSwitchboard upgradeOld fuses or no safety switches? Save on a new switchboard.
  • $60 offYour first jobNew customers save on their first booked job.

The $0 call-out is for booked jobs: a time we have set together, with the work going ahead. It applies Monday to Friday, 7am to 5pm. After-hours emergency call-outs have a minimum charge of $349 + GST, and Lachie confirms it on the phone before he drives out.

What trips a circuit breaker

A circuit breaker protects the cable in your walls. It trips when that cable carries more than it's built for: slowly for an overload, instantly for a short.

Where the fault is when your safety switch keeps trippingA switchboard with one safety switch tripped and one circuit breaker off. Its circuit runs through the house to a kettle sparking at its base, a cable in the wall with a nail through it, an outdoor light in the rain with water inside, and a power board overloaded with a heater. Switchboard Outside 12345
What the numbers show
  1. Safety switch or circuit breaker?
  2. A faulty appliance
  3. Water in an outdoor light or power point
  4. A damaged cable
  5. Too much on one circuit
What you're looking at: Your switchboard is on the left, with one safety switch tripped (in red). The line running from it is one circuit, and along it are the usual culprits: a kettle leaking power, a nail through a cable in the wall, an outdoor light letting in rain, and a power board with too much plugged in.Simplified drawing. Red shows the fault or a switch that has tripped. Every property is different: Lachie will show you what's going on at yours.
  1. Safety switch or circuit breaker?

    Check which one dropped. A narrow breaker labelled by circuit means overload or a short. A wider switch with a test button is a safety switch, which trips on leaking power.

  2. A faulty appliance

    An appliance with a short inside, from a burnt element, a failed motor or a damaged cord, trips the breaker the moment it's switched on.

  3. Water in an outdoor light or power point

    Enough water in a fitting can short it out and trip the breaker, not just the safety switch. Outdoor power points and lights are the usual ones.

  4. A damaged cable

    A nail or screw through a cable can short it. If the breaker trips the instant you reset it, with everything unplugged, the wiring is the suspect.

  5. Too much on one circuit

    The most common cause. Heaters, kettles, air fryers and microwaves each draw a lot. Two or three on one circuit and the breaker trips, usually after a few minutes.

What usually trips a breaker: more detail on each cause

Most of the time it's doing its job: protecting the cable in your walls from more current than it was built to carry.

  • Too much on one circuit Most common

    A 2,400 watt heater or kettle draws about 10 amps, and most power circuits are protected at 16 or 20 amps. Run a heater, kettle and toaster together and the breaker trips.

  • A faulty appliance

    A burnt element, a failed motor or a damaged cord can short out inside an appliance. The breaker trips the instant it's switched on, even on a quiet circuit.

  • A short in the wiring

    A nail through a cable, a burnt power point or a failed light fitting lets live touch neutral or earth. The breaker trips straight away, every time.

  • A loose connection at the breaker

    Where the cable connects to the breaker, a loose terminal heats up and makes it trip below its rating. Left alone, it can damage the board.

  • A worn-out breaker Less common

    Breakers can weaken with age and trip early. We measure the load first, because a breaker that trips on a real overload is working as it should.

  • Not enough circuits for how you live Older homes

    Older homes were wired for a fridge, a kettle and a few lights. Add heaters, air fryers, a home office and a second fridge, and the circuits can't keep up.

How it trips tells us why

Breakers trip in two ways. Which one you're seeing narrows the cause straight away.

  • It trips after a few minutes of heavy use

    The heater has been on a while, the kettle goes on, and a few minutes later the breaker drops. That's an overload. The breaker is protecting the cable from overheating.

  • It trips the instant one thing goes on

    That's more likely a short inside that appliance. Leave it unplugged and have it checked.

  • It trips the moment you reset it

    The fault is there right now. Unplug everything on that circuit. If it still won't stay on, leave it off and call.

  • It only trips in winter, or in summer

    Heaters and electric blankets in winter, portable air cons in summer. Seasonal tripping is almost always load.

  • A hot smell or marks near the breaker

    A loose connection on a breaker heats it, and heat makes it trip early. Discolouring, buzzing or a hot smell at the board means leave it off and call.

  • One area keeps going off

    Often the kitchen or living area, where the kettle, toaster, microwave, heater and air fryer all live. In older homes, one circuit can cover half the house.

How we fix it

We measure before we change anything, so the fix matches the real cause.

  1. 1

    Talk it through on the phone

    Lachie asks which breaker trips, what's usually running and whether it goes suddenly or after a while. A photo of the switchboard and its labels helps.

  2. 2

    Measure the load

    With your usual appliances running, he measures what the circuit actually draws with a clamp meter. That shows straight away whether it is overloaded.

  3. 3

    Test the circuit and the breaker

    He tests the wiring for shorts and damage, checks the connections at the breaker for heat, and tests any appliance that trips it instantly.

  4. 4

    Fix it properly

    That might mean moving appliances, a new circuit for the heavy ones, remaking a loose connection, replacing a breaker or repairing a short. We price it first and you decide. You get a Certificate of Compliance for Electrical Work (CCEW) where the work needs one.

Spread the load, add a circuit, or upgrade the board: your options side by side

If it's overload, the answer is more capacity where you use it. If it's a fault, we fix the fault.

Spread the load

A breaker that only trips when two heavy appliances run together

  • No work needed. We show you which power points share a circuit.
  • Relies on everyone remembering. It's a workaround, not a fix.
  • As long as the habits stick.

Add a new circuit, or split this one

Kitchens, home offices and living areas that run several heavy appliances

  • Heavy appliances get their own circuit, so they stop tripping each other.
  • New cable from the board, and the board needs room for another breaker.
  • Permanent.

Upgrade the switchboard

Full boards, old ceramic fuses, or a board showing heat damage

  • Room for new circuits, and a safety switch on every one.
  • The biggest job, with the power off while it's done. Meter or service fuse work is Ausgrid or Level 2 work.
  • Many years, with room for air con, solar or an EV charger later.

Never fit a bigger breaker to stop the tripping. The breaker is sized to the cable in your walls. A bigger one lets the cable overheat, and that can start a fire inside the wall.

What you can safely do now

These are safe for anyone. Anything inside the switchboard or a power point is licensed work.

Safe to do now

  • Turn off or unplug the heavy appliances on that circuit, if they're dry and safe to touch.
  • Reset the breaker once. If it trips again straight away, leave it off.
  • Until it is fixed, run the heater, kettle and air fryer one at a time, not together.
  • Note what was running when it tripped and how long it took. Take a photo of the board.

Don't

  • Don't keep resetting it or hold it on. It's protecting the cable in your wall.
  • Don't run heavy appliances through double adaptors or power boards to get around it.
  • Don't fit, or ask anyone to fit, a bigger breaker.
  • Don't touch the board if it's scorched, buzzing or smells hot.

Call straight away if

  • It trips the moment you reset it, even with everything unplugged.
  • There's a hot smell, buzzing or discolouring at the breaker or a power point. Switch off the main switch if it's safe to reach. If there's smoke or fire, call 000 and never put water on it.
  • A power point or plug on that circuit feels warm or looks scorched.
  • The fridge, freezer or medical equipment is on the circuit that is off.
Call Lachie

What locals say

5.0 from 24 Google reviewsWord for word, nothing edited.

  • We have had Lachie from Cazlec do a lot of work on our home in Merewether. He has always been honest and reliable and we know he will enjoy many years of success.

    todd blatchford, Merewether Google review

  • I've used Lachie @ Cazlec on several occasions now and highly recommend. He does a great job, is reliable, on time, and always leaves everything clean and tidy. Pricing is very fair as well.

    Doug Norton Google review

  • We have the pleasure of working with Lachie and his team at Clarke & Co Property Management for both emergency call-outs and general maintenance work. Lachie is always quick to respond, professional, and happy to help whenever needed. His communication and workmanship are consistently excellent.

    Calais Horrigan Google review

  • Cazlec (Lachlan) did a thorough and tidy job for a very reasonable price. Prompt and professional, I'll happily refer him to others. Thanks!

    Samuel Roberts Google review

  • We've been using Cazlec Electrical for our business and have always been impressed with the quality of service. They arrive when they say they will, and take the time to explain any issues and solutions clearly.

    Bobby Google review

  • Lachlan and his team have been extremely prompt when we have needed an electrician. They are professional and personable and would highly recommend them. No job too small.

    Marie Smith Google review

  • We have used Cazlec Electrical on a number of occasions and have always had a quick response and have been extremely pleased with the work they have done. I would highly recommend this company.

    Terence Coombes Google review

  • I have been using Cazlec Electrical for the last 3 years. Always on time. No hassle and gets the job done. Highly recommend.

    steven thomas Google review

  • Professional and outstanding tradesmen.

    Rob Iacopetta Google review

  • Highly recommend. Great service!

    Sharyn Rogers Google review

More reviews

Questions people ask

Why does my circuit breaker keep tripping?

Usually there's more on that circuit than it's built to carry, like a heater and kettle together. Less often it's a short in an appliance or the wiring, a loose connection or a worn breaker. Measuring the load and testing the circuit tells us which.

Why won't my breaker reset?

Either the fault is still there, or the breaker needs to cool. After an overload, give it a few minutes and try once. If it trips the moment it's on, even with everything unplugged, there's a short. Leave it off and call.

What's the difference between a circuit breaker and a safety switch?

A circuit breaker protects the cable from too much current or a short. A safety switch (RCD) protects people, cutting the power if current leaks to earth. Breakers are narrow and labelled by circuit. Safety switches are wider, with a test button.

Can I put in a bigger breaker?

No. The breaker is matched to the cable in your walls. A bigger one would let the cable carry more than it's built for and overheat. If you need more power in one area, the fix is a new circuit, not a bigger breaker.

How many heavy appliances can one circuit run?

It depends on the circuit, so we measure it. As a guide, a 2,400 watt heater or kettle draws about 10 amps, and most power circuits are protected at 16 or 20 amps. Two at once can be enough to trip it.

Can you come today?

Often, yes. Lachie works Monday to Friday, 7am to 5pm, and takes urgent calls from 4am to 9:30pm, 7 days across Newcastle & Lake Macquarie. Call 0402 079 953.

Lachie

Get a free quote from Lachie

Four quick details and Lachie will be in touch. Your quote is back within 24 hours, with no hidden fees.

  • Free quotes. Back to you within 24 hours, in plain English, with no hidden fees.
  • Upfront pricing. You know the cost before any work starts.
  • 100% satisfaction guarantee. Not happy with the work? Lachie comes back and makes it right, free.
  • Quality guarantee. Every job done to the Australian wiring rules (AS/NZS 3000), with parts that meet Australian standards, and tested before we leave.

Rather talk it through? Call Lachie on 0402 079 953

We use your details only to quote and book this job. Privacy.