Available nowNewcastle, Lake Macquarie & the Hunter · Urgent calls 4am–9:30pm, 7 days

Often fixed the same day

Breaker trips when the microwave or heater is on? We'll fix the overloaded circuit

Microwaves, heaters and hair dryers are heavy loads. Together on one circuit, they trip it. Lachie finds what's on it, then spreads the load or adds a circuit.

5.0 from 24 Google reviewsUpfront pricesLicensed & insured

Chandelier, wall light and under-cabinet lighting in a kitchen and dining room

Offers on this job

  • $0Call-out feeOn booked jobs, Monday to Friday, 7am to 5pm.
  • $200 offSwitchboard upgradeOld fuses or no safety switches? Save on a new switchboard.
  • $60 offYour first jobNew customers save on their first booked job.

The $0 call-out is for booked jobs: a time we have set together, with the work going ahead. It applies Monday to Friday, 7am to 5pm. After-hours emergency call-outs have a minimum charge of $349 + GST, and Lachie confirms it on the phone before he drives out.

Too much on one circuit

One circuit feeds several power points. A microwave, kettle, air fryer and heater on it at once can add up to more than its breaker allows.

A kitchen circuit overloaded by a microwave, kettle, air fryer and heaterA kitchen bench with a microwave, kettle and air fryer all plugged into one power board, which plugs into a warm power point. A heater on the floor plugs into another power point on the same circuit. At the switchboard, that circuit breaker has tripped while the safety switches are still on. Switchboard Heater 12345
What the numbers show
  1. Heavy appliances together
  2. A heater on the same circuit
  3. One circuit, several power points
  4. The circuit breaker trips, not the safety switch
  5. A warm power point
What you're looking at: A kitchen bench with a microwave, kettle and air fryer all on one power board, plus a heater on the next power point along. They all share one circuit, so its breaker at the switchboard has tripped (in red). The safety switches are still on.Simplified drawing. Red shows the fault or a switch that has tripped. Every property is different: Lachie will show you what's going on at yours.
  1. Heavy appliances together

    A microwave, kettle, toaster or air fryer each draw a lot. Run two or three at once from the bench power points or one power board and the total adds up fast.

  2. A heater on the same circuit

    A power point across the room is often on the same circuit. A heater that has been on a while, plus the kitchen, is the classic trip on a cold night.

  3. One circuit, several power points

    You can't tell from the wall which power points share a circuit. Older homes often have only one or two power circuits for the whole house.

  4. The circuit breaker trips, not the safety switch

    The breaker is protecting the wiring from overheating. Switch some things off, then reset it once. If one appliance trips it on its own, that appliance is faulty.

  5. A warm power point

    A plate that is warm, discoloured or smells hot means a connection is overheating. Switch that circuit off at the switchboard and call.

What usually causes it: more detail on each cause

Most of the time the breaker is doing its job: the circuit is being asked for more than it can safely carry.

  • Too many heavy appliances on one circuit Most common

    One circuit feeds several power points, often a whole room or two. Microwaves, kettles, heaters, hair dryers and air fryers each draw a lot. Run two or three at once and the total trips the breaker.

  • Older homes with fewer circuits Older homes

    Many older homes have one or two power circuits for the whole house, built for far less than we plug in today. The kitchen, bedrooms and lounge can all share one breaker.

  • A loose connection at the breaker

    A loose terminal at the breaker warms it up, so it trips sooner, at a load it would normally carry. A loose one at a power point won't trip anything, but it overheats. Either needs finding.

  • A faulty appliance

    A heater element or microwave part that's shorting trips the breaker instantly, or leaks and trips the safety switch. That's the appliance, not your wiring. Microwaves hold a dangerous charge inside, so never open one.

  • A new appliance or a renovation

    A new air fryer, coffee machine or oil heater, or extra power points added onto an old circuit, can push it past its limit.

  • A worn breaker Less common

    Breakers can weaken with age and trip below their rating. It's not common, so we measure the load before we blame the breaker.

When it trips tells us what's overloading it

A circuit breaker trips for too much load or a short. A safety switch trips for a leak. Check which one went first.

  • It trips when the microwave and kettle run together

    Kitchen bench power points are often on one circuit. A microwave, kettle, toaster or air fryer at once can add up to more than the breaker allows.

  • It trips when the heater's been on a while

    A breaker that goes after 10 or 20 minutes is warming up under a load near its limit. Heaters on a cold night, with other things on, are the classic case.

  • It trips when the hair dryer goes on

    A hair dryer on high, with a heater or straightener in the same room, can tip a bedroom or bathroom circuit over.

  • One appliance trips any circuit

    If one appliance trips every circuit it goes on, even alone, the appliance is faulty, not the circuit overloaded. Stop using it.

  • A warm power point or a hot smell

    A plate that is warm, discoloured or smells hot means a connection is overheating. Switch that circuit off at the switchboard and call.

How we fix it

We find out what's on the circuit and what it draws, then give you options to stop the trips.

  1. 1

    Talk it through on the phone

    Lachie asks what was running when it tripped, which breaker went and which rooms go off with it. A photo of your switchboard helps.

  2. 2

    Map the circuit

    He works out every power point on that breaker. Most people are surprised how much one circuit covers.

  3. 3

    Measure the load and test the wiring

    With your usual appliances running, he measures what the circuit draws against the breaker rating. He tests the wiring and checks the power points and breaker terminals for heat damage.

  4. 4

    Fix it and show you

    You get the price before any work starts. That might be moving appliances to other circuits, remaking a loose connection, extra power points on another circuit, or a new circuit for the kitchen or heater. You get a Certificate of Compliance for Electrical Work (CCEW) where the work needs one.

Spread the load, add a circuit, or upgrade the board: your options side by side

Most overloaded circuits are fixed by spreading the load. The board only comes into it if there is no room left.

Spread the load

A circuit that trips only when two heavy appliances run together

  • We show you which power points are on which circuit, so you can move the microwave or heater. It may need little or no work.
  • Relies on habits, and doesn't help if every room is on one circuit.
  • As long as the habits stick.

Extra power points or a new circuit

Kitchens, bedrooms or living areas with too few circuits for what you use

  • The microwave, heater or kettle gets its own supply, with safety switch protection, and stops tripping the rest.
  • New cable through walls or ceilings, and room needed on the board.
  • For good.

Upgrade the switchboard

Old ceramic fuse boards, boards with no spare room, or homes with only one or two power circuits

  • More circuits, every one protected and labelled, with room for air con or solar later.
  • The biggest job, and the power is off while it's done.
  • A new board built to current wiring rules.

Never fit a bigger breaker to stop the trips. The breaker is sized to protect the cable, and a bigger one lets the cable overheat inside the wall.

What you can safely do now

These are safe for anyone. Inside the switchboard and the power points is a licensed electrician's job.

Safe to do now

  • Turn off and unplug the microwave, heater or hair dryer, if the plug is dry, cool and safe to touch.
  • Reset the breaker once. If it trips straight away with nothing on, leave it off.
  • Until it is checked, avoid running two heavy appliances on that circuit at once.
  • Note what was running and which rooms went off, and take a photo of the switchboard.

Don't

  • Don't hold the breaker on or tape it up. It's stopping the cable overheating.
  • Don't use power boards or double adaptors to run heaters and other heavy appliances.
  • Don't open a microwave or heater to look for the fault. Microwaves hold a dangerous charge even when unplugged.
  • Don't keep using an appliance that trips every circuit you plug it into.

Call straight away if

  • The breaker trips straight away with nothing plugged in.
  • A power point or plug is warm, scorched or smells hot. Switch that circuit off at the switchboard if it's safe. Smoke or fire: call 000, and never put water on it.
  • You feel a tingle from an appliance, a tap or the shower. Keep everyone away and call Ausgrid on 13 13 88 first, then us.
  • The fridge or medical equipment is on the circuit that keeps going off.
Call Lachie

What locals say

5.0 from 24 Google reviewsWord for word, nothing edited.

  • We have had Lachie from Cazlec do a lot of work on our home in Merewether. He has always been honest and reliable and we know he will enjoy many years of success.

    todd blatchford, Merewether Google review

  • I've used Lachie @ Cazlec on several occasions now and highly recommend. He does a great job, is reliable, on time, and always leaves everything clean and tidy. Pricing is very fair as well.

    Doug Norton Google review

  • We have the pleasure of working with Lachie and his team at Clarke & Co Property Management for both emergency call-outs and general maintenance work. Lachie is always quick to respond, professional, and happy to help whenever needed. His communication and workmanship are consistently excellent.

    Calais Horrigan Google review

  • Cazlec (Lachlan) did a thorough and tidy job for a very reasonable price. Prompt and professional, I'll happily refer him to others. Thanks!

    Samuel Roberts Google review

  • We've been using Cazlec Electrical for our business and have always been impressed with the quality of service. They arrive when they say they will, and take the time to explain any issues and solutions clearly.

    Bobby Google review

  • Lachlan and his team have been extremely prompt when we have needed an electrician. They are professional and personable and would highly recommend them. No job too small.

    Marie Smith Google review

  • We have used Cazlec Electrical on a number of occasions and have always had a quick response and have been extremely pleased with the work they have done. I would highly recommend this company.

    Terence Coombes Google review

  • I have been using Cazlec Electrical for the last 3 years. Always on time. No hassle and gets the job done. Highly recommend.

    steven thomas Google review

  • Professional and outstanding tradesmen.

    Rob Iacopetta Google review

  • Highly recommend. Great service!

    Sharyn Rogers Google review

More reviews

Questions people ask

Why does my breaker keep tripping when I use the microwave?

Usually the microwave shares a circuit with other heavy appliances, like the kettle, toaster or air fryer, and the total is too much. If it trips the moment the microwave starts, even on its own, the microwave may be faulty.

Why does the heater keep tripping the power?

Heaters draw close to a power point's full rating for hours. Add another heater, a hair dryer or an electric blanket on the same circuit and the breaker trips. If the safety switch trips instead, the heater may be leaking current, so stop using it.

Why does my hair dryer trip the circuit breaker?

A hair dryer on high is one of the heaviest things most people plug in. On a shared bedroom or bathroom circuit, with a heater or straightener on, it tips the breaker over. If it trips on its own, the dryer may be faulty.

Is it the appliance or the circuit?

If it only trips when several things run together, it's the circuit. If one appliance trips it instantly, wherever it's plugged in, it's the appliance. We measure the load and test the wiring to be sure.

Do I need a switchboard upgrade?

Not usually. Most overloaded circuits are fixed by spreading the load or adding a circuit. If your board has ceramic fuses, no room for new circuits or no safety switches, an upgrade may be the way to go. Lachie tells you straight, and you decide.

Can you come today?

Often, yes. Lachie works Monday to Friday, 7am to 5pm, and takes urgent calls from 4am to 9:30pm, 7 days. Call 0402 079 953 and you get the price before any work starts.

Lachie

Get a free quote from Lachie

Four quick details and Lachie will be in touch. Your quote is back within 24 hours, with no hidden fees.

  • Free quotes. Back to you within 24 hours, in plain English, with no hidden fees.
  • Upfront pricing. You know the cost before any work starts.
  • 100% satisfaction guarantee. Not happy with the work? Lachie comes back and makes it right, free.
  • Quality guarantee. Every job done to the Australian wiring rules (AS/NZS 3000), with parts that meet Australian standards, and tested before we leave.

Rather talk it through? Call Lachie on 0402 079 953

We use your details only to quote and book this job. Privacy.