Does your switchboard need upgrading? The signs we look for, and a straight answer
Ceramic fuses, no safety switches, heat marks or no room for new circuits usually mean yes. A newer board with safety switches is often fine. We check and tell you.
5.0 from 24 Google reviewsUpfront pricesLicensed & insured

Offers on this job
- $0Call-out feeOn booked jobs, Monday to Friday, 7am to 5pm.
- $200 offSwitchboard upgradeOld fuses or no safety switches? Save on a new switchboard.
- $60 offYour first jobNew customers save on their first booked job.
The $0 call-out is for booked jobs: a time we have set together, with the work going ahead. It applies Monday to Friday, 7am to 5pm. After-hours emergency call-outs have a minimum charge of $349 + GST, and Lachie confirms it on the phone before he drives out.
The five things we check on your board
Open the switchboard door and look, without touching anything inside. Here's what each part tells us.
- Ceramic (rewireable) fuses
- No safety switches
- An old backing board
- No room for anything new
- The new board
Ceramic (rewireable) fuses
White ceramic fuse holders instead of switches mean an older board. On their own, they're the clearest sign an upgrade is worth pricing.
No safety switches
Look for a button marked T or Test. None, or one for the power points only, means some circuits have no protection against a shock.
An old backing board
A dark, fibrous panel behind everything may contain asbestos. It's fine left alone, but nothing can be added to it.
No room for anything new
No empty spaces means nowhere for a new circuit for air con, an induction cooktop, solar or an EV charger.
The new board
If we do recommend an upgrade, this is what you get: safety switches on every circuit, everything labelled, and room to add more.
A straight answer: when it does, and when it doesn't: more detail on each cause
Plenty of boards don't need replacing. Here's how we decide.
Ceramic fuse boards: usually yes Upgrade
Rewireable fuses protect the wiring, not people, and have often been rewired with the wrong wire. There's rarely room to add safety switches, so a new board is usually the sensible fix.
Breakers but few safety switches: maybe Depends
If the board is in good condition and has room, adding safety switches can be enough. If it's full or tired, an upgrade makes more sense.
Safety switches on every circuit: usually not Often fine
A newer board with safety switches throughout, spare space and no heat marks rarely needs replacing. A fault on one circuit is fixed on that circuit.
Adding solar, a battery or an EV charger: often Planning
Each needs its own space or circuit on the board, and a full board has nowhere to put it. Sometimes the supply or meter box needs upgrading too.
An asbestos backing board: when you need work done Older homes
An intact panel can stay while nothing needs doing. Once you need a new circuit or meter, it has to be replaced. We do that, with the asbestos handled by a licensed asbestos professional we work with, to SafeWork NSW rules.
Heat damage: yes, and soon Urgent
Scorch marks, melting or a burning smell mean part of the board is failing. We repair what is urgent now, and you plan the rest.
Signs it needs upgrading
Any one of these is worth a check. Two or more, and an upgrade is usually the better option.
Ceramic fuses
If your board has fuse holders you pull out, not switches you flick, it's a rewireable fuse board, and it's old.
Few or no test buttons
Each safety switch has a T or Test button. If there are none, or just one for the power points, some circuits have no shock protection.
Trips or blown fuses that keep happening
Once is usually an appliance. If it keeps happening with nothing faulty, the circuits are overloaded or the board is too small for the house.
Heat, a smell, scorch marks or buzzing
These mean a connection is overheating. That's not a sign for later. Switch off the main switch if it's safe, and call.
No room left
There are no empty spaces on the board, or an installer has told you they can't add your air con, solar or EV charger.
How we check your board
A board check is a look and some tests, not guesswork. You get a straight answer and a price for each option.
- 1
Look at the board and the meter box
Lachie checks the fuses or breakers, the safety switches, the backing panel, the labels and the space left. He also looks for heat marks, loose parts and water getting in.
- 2
Test what matters
He checks the safety switches trip as they should, checks the earthing, and tests the circuits that give you trouble.
- 3
Ask what you plan to add
Air con, an induction cooktop, solar, a battery or an EV charger all change the answer. Tell us now, so the advice fits the next ten years, not just today.
- 4
A straight answer, and a price for each option
You hear whether the board is fine, needs safety switches added, or needs replacing, and why. You get the price for each before any work starts, and you decide. No pressure either way.
Keep it, add safety switches, or upgrade: your options side by side
Most people reading this are still deciding. Here's the honest comparison. You get the price for each before any work starts.
If your board is fine, we'll say so. An upgrade is worth it when it adds protection or room you need, not because a board looks old. New and altered circuits need safety switch protection under the wiring rules (AS/NZS 3000), which is often what brings the board into it.
What you can safely do now
An old board on its own isn't an emergency. A hot, smelly or wet one is.
Safe to do now
- Open the door and take a photo of the board, without touching anything inside. Send it with the form.
- Write down what you plan to add, like air con, solar or an EV charger.
- Note how often things trip or fuses blow, and what was running.
- Keep kids away from the meter box.
Don't
- Don't put fuse wire, or anything else, into a blown ceramic fuse.
- Don't drill or screw into the backing board. Older ones may contain asbestos.
- Don't take covers off the board, or touch it if it's wet, scorched or warm.
Call straight away if
- A burning smell, buzzing, crackling or scorch marks at the board. Switch off the main switch if it's dry and safe to reach, then call. Smoke or fire: call 000, never water.
- Water has got into the switchboard or meter box: keep clear and call.
- You feel a tingle or shock from a tap or the shower: call Ausgrid on 13 13 88, then us.
- A switch trips straight back off and you need power for a fridge or medical equipment.
Questions people ask
Do I need to upgrade my switchboard?
If it has ceramic fuses, no safety switches, heat marks or no room for what you want to add, probably yes. If it's a newer board with safety switches throughout, probably not. We check it and tell you which, with a price for each option.
How old is too old for a switchboard?
Age alone does not decide it. What matters is ceramic fuses, missing safety switches, heat damage, an asbestos panel and room to grow. Some older boards are fine with safety switches added. Some newer ones are already full.
Can I just add safety switches instead?
Sometimes. If the board has breakers, is in good condition and has room, adding safety switches is a sensible, smaller job. Ceramic fuse boards and full boards rarely have room, so a new board usually makes more sense there.
Will my switchboard handle solar or an EV charger?
It depends on space, the safety switches and your supply. Check before you sign a quote, so a board upgrade isn't a surprise added later. Our page on switchboards for solar and EV chargers covers it.
Are safety switches compulsory in older homes?
New and altered circuits must have them under the wiring rules (AS/NZS 3000). Existing homes and rentals are not covered by the same rule, but in a NSW rental any electrical fault, including a faulty safety switch, is treated as an urgent repair. Either way, they protect people from a serious shock, so we recommend them on every circuit.
How long does a switchboard check take?
Usually a short visit. We look at the board, test the safety switches and talk through your plans, then send the options with a price for each. If we find anything urgent, we tell you on the spot.

Get a free quote from Lachie
Four quick details and Lachie will be in touch. Your quote is back within 24 hours, with no hidden fees.
- Free quotes. Back to you within 24 hours, in plain English, with no hidden fees.
- Upfront pricing. You know the cost before any work starts.
- 100% satisfaction guarantee. Not happy with the work? Lachie comes back and makes it right, free.
- Quality guarantee. Every job done to the Australian wiring rules (AS/NZS 3000), with parts that meet Australian standards, and tested before we leave.
Rather talk it through? Call Lachie on 0402 079 953