Why a power point gets hot or smells
Heat at a power point means power is struggling to get through: a loose connection, a worn socket or too much plugged in. Heat leads to melting, then fire, so it can't wait.
- A loose connection behind the plate
- Too much on one power point
- A worn socket that doesn't grip
- A damaged cord or plug
- The switchboard: where you switch it off
A loose connection behind the plate
The most common cause. A wire works loose on its screw, the join heats up, and you smell it before you see it. Scorch marks or a buzzing sound are warnings.
Too much on one power point
A double adaptor plus a power board running a heater, kettle or air fryer can pull more than the power point and its wiring are built for.
A worn socket that doesn't grip
If plugs fall out or feel loose, the contacts inside are worn. Poor contact makes heat and sparks.
A damaged cord or plug
A cord that is cracked, kinked or squashed under furniture can overheat along its length. Stop using it.
The switchboard: where you switch it off
Switch that circuit off at the switchboard (or the main switch) if the board is dry and safe to reach. Then don't use that power point until it's fixed.
What usually causes it: more detail on each cause
It comes down to one thing: current pushing through a poor contact. Here is how that contact goes bad.
Connections that loosen over the years Most common
Each time an outlet carries a load, the terminals warm up and cool down. Over years, screws can loosen and copper can corrode. A poor joint resists the current and heats up, which loosens it further. It's hidden behind the plate, so the smell is often the first sign.
Heaters, kettles and power boards
Heaters, kettles and air fryers can draw close to the 10 amps a standard power point is rated for. Run two through a double adaptor or power board and the outlet can overheat before the breaker trips.
Outlets that don't grip any more
The spring contacts inside an outlet lose their grip with age and use. A plug that sits loose touches on a small area, and that small area runs hot. Cracked plates wear faster.
Damaged cords and plugs
A cord crushed under furniture, kinked or chewed by a pet can overheat inside. So can a bent pin. Scorching only on the plug can point here, but we check the outlet as well.
Old wiring and old switchboards Older homes
Older homes may have rubber-covered wiring that has gone brittle, and boards with ceramic fuses and no safety switches. Fuses and breakers react to too much current, not to heat at one loose joint, so a loose joint can overheat without anything tripping.
Signs a power point or switch is overheating
Any one of these means heat where there should be none. Switch that circuit off and call.
The plate or plug feels warm
A power point should feel the same as the wall around it. Warmth, even with a small appliance plugged in, means a connection is struggling.
A burning or fishy smell
Overheating plastic smells of burning, and some plastics in outlets and plugs smell oddly fishy. Either way, the cause is heat.
Brown or black marks
Scorch marks on the plate or around the pins mean arcing has already happened, at the plug or behind the plate.
Sparks, crackling or a buzzing switch
Electricity jumping a gap is called arcing. You may see it as a spark or hear it as a crackle or buzz.
A melted or loose plug
Discoloured pins, a soft or misshapen plug, or a plug that won't stay in all point to heat at the contact.
How we fix it
We make it safe first, find out why it overheated, then fix the cause so it doesn't come back.
- 1
Make it safe
We isolate the circuit at the switchboard, prove it is dead, and take the plate off. You see what we see: the scorched terminal, the loose screw or the melted plug.
- 2
Find the cause
We check the terminals, the cable behind the outlet, and the other outlets on the same circuit, because a loose joint at one can show up at the next. We also look at what's plugged in and how it's used.
- 3
Price it before we fix it
You get an upfront price with no hidden fees before any work starts. If the heat has damaged the cable, we tell you, and price cutting it back or running new cable.
- 4
Replace, test and sign off
We fit a new outlet or switch, test the circuit and its safety switch, and check it under load. Where the job needs one, you get a copy of the Certificate of Compliance for Electrical Work (CCEW).
Replace the outlet, add more, or give it its own circuit: your options side by side
Once it is safe, the right fix depends on what caused the heat.
Replacing a damaged outlet doesn't usually need any switchboard work. New or altered circuits do need safety switch (RCD) protection under the wiring rules (AS/NZS 3000), so if your board has none, we include it in the price for those jobs.
What you can safely do now
Heat at a power point or switch is a fire risk. Make it safe first, then call.
Safe to do now
- Switch that circuit off at the switchboard. If you can't tell which breaker it is, use the main switch. Only do this if the board is dry, undamaged and safe to reach.
- Unplug the appliance only if the plug isn't hot, melted or sparking. If it is, leave it plugged in with the circuit switched off.
- Leave that outlet unused until it's checked. Stick a note on it so nobody plugs in by mistake.
- Keep kids and pets away from it.
- Call Lachie now on 0402 079 953.
- Take photos of any marks or melted plugs, for us and for your insurer.
Don't
- Don't put water on an electrical fire, or on a power point that is smoking.
- Don't touch a plug or outlet that is hot, melted or sparking, and don't pull on the cord.
- Don't take the cover off or try to tighten anything. In NSW, electrical work must be done by a licensed electrician.
- Don't touch the switchboard if it is wet, scorched or smoking.
- Don't go back to using it because the smell has gone. The fault is still there.
Call straight away if
- There is smoke or fire. Get everyone out, close the door behind you and call 000. Never put water on an electrical fire.
- You can hear crackling or buzzing in the wall, or still smell burning after the circuit is off.
- You get a tingle or shock from a tap, shower or appliance. Call Ausgrid on 13 13 88 and keep everyone clear.
- More than one outlet or switch is warm, or the lights are flickering as well.
Questions people ask
Is a hot power point an emergency?
Yes. A power point should feel no warmer than the wall. Heat means a connection is breaking down, and it can start a fire inside the wall. Switch that circuit off at the switchboard if it's safe, don't use the outlet, and call. If there is smoke or fire, call 000.
Why does my power point smell like burning, or like fish?
Both smells come from plastic overheating. The cause is usually a loose connection or an overloaded outlet. Switch the circuit off and have it checked before you use it again, even if the smell fades.
Why didn't the breaker trip?
Breakers and fuses react to too much current, not to heat at one loose joint. A connection can overheat on a normal load without the circuit drawing more than it should. That's why a burning smell needs checking even when nothing has tripped.
Are power boards and double adaptors safe?
Used sensibly, yes. The trouble is stacking heavy appliances on one outlet. A heater, kettle or air fryer can draw close to the 10 amps a standard power point is rated for, so two at once overloads it. Keep to one heavy appliance per outlet, and ask us about more outlets if you're short.
Can you come tonight?
Yes. Lachie takes urgent calls from 4am to 9:30pm, 7 days. Call 0402 079 953, tell us what you can see and smell, and keep that circuit switched off at the switchboard while you wait.
Can the power point be repaired, or does it need replacing?
It's replaced, not repaired. Once an outlet has overheated, the plastic and the spring contacts inside are damaged and won't grip properly again. If the cable behind it is heat-damaged too, we cut it back to clean copper or run new cable.

Get a free quote from Lachie
Four quick details and Lachie will be in touch. Your quote is back within 24 hours, with no hidden fees.
- Free quotes. Back to you within 24 hours, in plain English, with no hidden fees.
- Upfront pricing. You know the cost before any work starts.
- 100% satisfaction guarantee. Not happy with the work? Lachie comes back and makes it right, free.
- Quality guarantee. Every job done to the Australian wiring rules (AS/NZS 3000), with parts that meet Australian standards, and tested before we leave.
Rather talk it through? Call Lachie on 0402 079 953