Available nowNewcastle, Lake Macquarie & the Hunter · Urgent calls 4am–9:30pm, 7 days

Urgent? Call Lachie now

Safety switch won't reset? Stop forcing it, we'll find what's holding it off

It's still sensing a fault, usually a plugged-in appliance, water or a damaged cable. Forcing it won't help. Lachie finds what's holding it off and gets your power back.

5.0 from 24 Google reviewsUpfront pricesLicensed & insured

Meter box with a smart meter, a main switch and a new row of labelled safety switches, on an older black backing board with an asbestos warning sticker

Offers on this job

  • $0Call-out feeOn booked jobs, Monday to Friday, 7am to 5pm.
  • $200 offSwitchboard upgradeOld fuses or no safety switches? Save on a new switchboard.
  • $60 offYour first jobNew customers save on their first booked job.

The $0 call-out is for booked jobs: a time we have set together, with the work going ahead. It applies Monday to Friday, 7am to 5pm. After-hours emergency call-outs have a minimum charge of $349 + GST, and Lachie confirms it on the phone before he drives out.

What's holding your safety switch off

A safety switch won't stay on while it can still sense a fault. It isn't stuck. It's refusing to power something that's leaking.

Where the fault is when your safety switch keeps trippingA switchboard with one safety switch tripped and one circuit breaker off. Its circuit runs through the house to a kettle sparking at its base, a cable in the wall with a nail through it, an outdoor light in the rain with water inside, and a power board overloaded with a heater. Switchboard Outside 12345
What the numbers show
  1. The safety switch that won't stay on
  2. An appliance still plugged in
  3. Water in an outdoor light or power point
  4. A damaged cable
  5. Too much on one circuit
What you're looking at: Your switchboard is on the left, with one safety switch tripped (in red). The line running from it is one circuit, and along it are the usual culprits: a kettle leaking power, a nail through a cable in the wall, an outdoor light letting in rain, and a power board with too much plugged in.Simplified drawing. Red shows the fault or a switch that has tripped. Every property is different: Lachie will show you what's going on at yours.
  1. The safety switch that won't stay on

    If the lever flicks straight back down, it's sensing a fault on one of its circuits right now. Try it once more with everything unplugged, then leave it.

  2. An appliance still plugged in

    A kettle, heater, fridge or washing machine with a worn element or motor can hold it off. Unplug everything on those circuits before you try again.

  3. Water in an outdoor light or power point

    After rain, a wet outdoor power point, garden light or pool pump can hold it off until things dry out. That isn't a fix.

  4. A damaged cable

    A nail through a cable, or rats chewing one in the roof, holds it off even with everything unplugged. This needs testing to find.

  5. Too much on one circuit

    If it's a narrow circuit breaker that won't go back on, not the safety switch, it may have tripped on overload and need a few minutes to cool first.

What usually holds it off: more detail on each cause

It's doing what it's built to do. The fault it's sensing is somewhere on its circuits.

  • A faulty appliance on the circuit Most common

    Worn elements in kettles, heaters, ovens and hot water systems, and ageing fridge or washing machine motors, leak power to earth. Plug-in ones can be unplugged. Hardwired ones need an electrician to isolate and test.

  • Water in a fitting

    Outdoor power points, garden and sensor lights, pool and spa equipment, and anything under a leaking roof or gutter. It can stay off until things dry, then trip again next rain.

  • A damaged cable

    Nails and screws from renovations, roof work, and rats or possums chewing cables in the roof. Older rubber-covered wiring also breaks down. These faults need testing to find.

  • A short or burnt connection

    If live is touching neutral or earth, at a burnt power point, a failed light fitting or a crushed cord, it trips the instant it goes on.

  • A failed safety switch Less common

    Safety switches do wear out. The lever may not latch, or it trips with no fault on the circuit. We test it before replacing it, because the switch is rarely the real cause.

  • One switch covering too much Older boards

    When one safety switch covers half the house, small leaks from every appliance add up, and a fault anywhere holds the whole lot off.

What the lever does tells us a lot

Try it once, watch what happens, and tell us when you call.

  • It flicks straight back off

    The fault is there right now, on a circuit that switch protects. With everything unplugged, it's most likely in the wiring or a hardwired appliance like the oven or hot water.

  • It stays on once things are unplugged

    Then one of the things you unplugged is the likely cause. Leave them unplugged until they've been tested.

  • The lever won't latch at all

    It springs back with no click. Either it's still sensing a fault, or its mechanism has failed. Don't force it.

  • It went after rain

    Water in an outdoor power point, garden light or pool gear can hold it off until things dry out. It will come back with the next rain.

  • It went with a bang, flash or burning smell

    That's a short circuit or a burnt connection, not just a leak. Leave it off and call now.

How we get it back on

We find what the switch is sensing, fix that, and only then put the power back on.

  1. 1

    Talk it through on the phone

    Lachie asks what the lever does, what's on that circuit and what you've unplugged. If there's a burning smell or water near the board, he'll tell you what to switch off first.

  2. 2

    Split up the circuits

    At the board, he isolates each circuit the safety switch covers and tests its wiring with an insulation resistance tester. The faulty circuit shows up, and the healthy ones can go back on.

  3. 3

    Find the faulty part

    On that circuit, he tests hardwired appliances, checks outdoor fittings and traces a damaged cable to where it's been hit. If the switch itself has failed, the test shows that too.

  4. 4

    Fix it, test it, power back on

    We repair or replace the faulty part, test that the safety switch trips as it should, and switch everything back on. If the board needs work, we explain why and price it first. You get a Certificate of Compliance for Electrical Work (CCEW) where the work needs one.

Fix the fault, replace the switch, or upgrade the board: your options side by side

Most of the time we fix the appliance, fitting or cable, and the safety switch goes back on.

Find and fix the fault

A sound board with a fault on one circuit

  • Fixes the cause, usually on the same visit, and keeps the safety switch doing its job.
  • A cable fault inside a wall or roof can take longer to trace.
  • For good, once the faulty part is repaired or replaced.

Replace the safety switch

A switch that tests faulty, or won't latch with no fault on the circuit

  • A quick fix when the switch itself is the problem.
  • Only worth doing once testing shows the switch is at fault. Otherwise the new one trips too.
  • Many years. Press its test button every few months.

A safety switch on every circuit

Older boards where one safety switch covers half the house

  • A fault only switches off its own circuit, so the fridge and lights stay on.
  • A bigger job. If the board is old or full, it may mean a new switchboard, priced first.
  • A board built to current wiring rules.

Never have a safety switch bridged out, removed or swapped for a plain breaker to get the power back on. It's what stands between that fault and a shock.

What you can safely do now

These are safe for anyone. Anything behind a cover is a licensed electrician's job.

Safe to do now

  • Unplug everything on the circuits that are off, if it's dry and safe to touch.
  • Try the safety switch once. If the lever is sitting halfway, push it fully off first, then up.
  • If it still won't stay on, leave it off.
  • Keep the fridge and freezer closed to hold the cold in.
  • Take a photo of the switchboard and note what was running when it went.

Don't

  • Don't keep flicking it, hold it up or tape it on. It's refusing to power a fault.
  • Don't touch the board if it's wet, scorched, buzzing or smells hot.
  • Don't open any cover, or run an extension lead from another circuit to work around it.
  • Don't plug things back in one by one to hunt for the fault. Let us test them.

Call straight away if

  • You rely on power for medical equipment, or the fridge, freezer or lights are on the circuit that is off.
  • It went with a bang, flash or burning smell. Switch off the main switch if it's safe to reach. If there's smoke or fire, call 000 and never put water on it.
  • Water is coming through a ceiling, light or fan. Keep clear, and switch off the main switch only if you can reach it without touching anything wet.
  • You feel a tingle or shock from a tap, the shower or an appliance. Keep everyone away and call Ausgrid on 13 13 88 first.
Call Lachie

What locals say

5.0 from 24 Google reviewsWord for word, nothing edited.

  • We have had Lachie from Cazlec do a lot of work on our home in Merewether. He has always been honest and reliable and we know he will enjoy many years of success.

    todd blatchford, Merewether Google review

  • I've used Lachie @ Cazlec on several occasions now and highly recommend. He does a great job, is reliable, on time, and always leaves everything clean and tidy. Pricing is very fair as well.

    Doug Norton Google review

  • We have the pleasure of working with Lachie and his team at Clarke & Co Property Management for both emergency call-outs and general maintenance work. Lachie is always quick to respond, professional, and happy to help whenever needed. His communication and workmanship are consistently excellent.

    Calais Horrigan Google review

  • Cazlec (Lachlan) did a thorough and tidy job for a very reasonable price. Prompt and professional, I'll happily refer him to others. Thanks!

    Samuel Roberts Google review

  • We've been using Cazlec Electrical for our business and have always been impressed with the quality of service. They arrive when they say they will, and take the time to explain any issues and solutions clearly.

    Bobby Google review

  • Lachlan and his team have been extremely prompt when we have needed an electrician. They are professional and personable and would highly recommend them. No job too small.

    Marie Smith Google review

  • We have used Cazlec Electrical on a number of occasions and have always had a quick response and have been extremely pleased with the work they have done. I would highly recommend this company.

    Terence Coombes Google review

  • I have been using Cazlec Electrical for the last 3 years. Always on time. No hassle and gets the job done. Highly recommend.

    steven thomas Google review

  • Professional and outstanding tradesmen.

    Rob Iacopetta Google review

  • Highly recommend. Great service!

    Sharyn Rogers Google review

More reviews

Questions people ask

Why won't my safety switch reset?

Because it can still sense power leaking somewhere on its circuits. Usually it's a faulty appliance, water in an outdoor fitting or a damaged cable. Less often the switch has failed. Unplug everything on those circuits, try it once, and if it still won't hold, call us.

Why won't my breaker switch back on?

If a narrow circuit breaker won't go back on, there's probably a short on that circuit. If it tripped from overload, give it a few minutes to cool, then try once. If it still won't hold, leave it off and call.

Can I just replace the safety switch?

Not yourself. Switchboard work is licensed work in NSW. And a new switch rarely fixes it, because the old one is usually working fine and sensing a real fault. We test the switch before replacing anything.

Is it safe to leave the power off?

Yes. A circuit that's off can't hurt anyone. The worry is what's on it, like the fridge or medical equipment. Keep the fridge closed, and tell us if anything vital is affected.

Will it reset once things dry out?

It might, if water caused it. But that only means the fitting has dried, not that it's fixed. It will trip again in the next rain, and a wet fitting can be live. Get it found and made weatherproof.

Can you come now?

Yes. Lachie takes urgent calls from 4am to 9:30pm, 7 days across Newcastle & Lake Macquarie, and works Monday to Friday, 7am to 5pm. Call 0402 079 953, tell us what's off and what the lever does, and leave it off while you wait.

Lachie

Get a free quote from Lachie

Four quick details and Lachie will be in touch. Your quote is back within 24 hours, with no hidden fees.

  • Free quotes. Back to you within 24 hours, in plain English, with no hidden fees.
  • Upfront pricing. You know the cost before any work starts.
  • 100% satisfaction guarantee. Not happy with the work? Lachie comes back and makes it right, free.
  • Quality guarantee. Every job done to the Australian wiring rules (AS/NZS 3000), with parts that meet Australian standards, and tested before we leave.

Rather talk it through? Call Lachie on 0402 079 953

We use your details only to quote and book this job. Privacy.