Often fixed the same day
Safety switch tripping every time it rains? We'll find where the water's getting in
Rain is getting into an outdoor power point, light, appliance or cable, and the safety switch cuts power to protect you. Lachie finds the wet fitting and fixes it.
5.0 from 24 Google reviewsUpfront pricesLicensed & insured

Offers on this job
- $0Call-out feeOn booked jobs, Monday to Friday, 7am to 5pm.
- $60 offYour first jobNew customers save on their first booked job.
The $0 call-out is for booked jobs: a time we have set together, with the work going ahead. It applies Monday to Friday, 7am to 5pm. After-hours emergency call-outs have a minimum charge of $349 + GST, and Lachie confirms it on the phone before he drives out.
Where the water gets in
Water and power only meet where a seal has failed, a lid's been left open or a cable's been damaged. The safety switch notices the leak and cuts the power.
- The safety switch that trips in the rain
- An appliance that lives outside
- Water in an outdoor light or power point
- A damaged cable
- Too much on one circuit
The safety switch that trips in the rain
It goes during or just after rain, and often resets once things dry out. That's the pattern of water, not a worn appliance.
An appliance that lives outside
Pool and spa pumps, outdoor hot water systems, air con units and a patio fridge all sit in the weather. A cracked seal lets water reach the wiring.
Water in an outdoor light or power point
The most common cause. Garden, sensor and eave lights, and outdoor power points with the lid left open or seals worn out.
A damaged cable
A garden cable buried too shallow and nicked by a spade, a cable in a wall that gets wet, or a joint in the roof under a leaking tile.
Too much on one circuit
If a narrow circuit breaker trips on wet days instead, it may be load, not water: the dryer, heaters and kettle all running while everyone's inside.
Where we usually find the water: more detail on each cause
It's almost always outside or in the roof, and almost always something we can see once we've tested the right circuit.
Outdoor power points Most common
Lids left open, worn seals, cracked covers, or an indoor-style power point fitted outside. Water sits across the pins and leaks power to earth.
Garden, eave and sensor lights
Sun and heat crack seals over the years. Water gets in and pools inside the fitting. Lights where the gutter overflows are the usual suspects.
Pool, spa and outdoor appliances
Pumps, chlorinators, outdoor hot water systems and the isolator switch beside an air con unit all live outside. When a seal or cover fails, water reaches the wiring.
A leaking roof or gutter
Water running through the roof can drip onto junction boxes, downlights or the top of a wall. It trips once the rain is heavy enough for the leak to start.
Buried or damaged outdoor cables Older homes
Cables to sheds, garages and garden lights are sometimes buried too shallow or without conduit. Spades and roots damage them, and wet ground does the rest.
Water in the meter box Less common
A meter box with a broken door seal or a gap in the wall can let rain onto the switchboard itself. Don't touch it if it's wet. Call us.
The pattern tells us it's water
Rain faults come and go with the weather, which is what makes them confusing. These are the clues.
It trips during heavy rain
Water is getting straight in, through an open power point lid, a cracked light, or a fitting under an overflowing gutter.
It trips hours after the rain stops
Water is soaking in slowly, through a wall, the roof or the ground around a buried cable, and takes time to reach the wiring.
It works again once it dries out
That's the classic sign. The fault hasn't gone. It's waiting for the next downpour.
It trips on dewy nights too
Condensation inside an outdoor light or sealed box can be enough. Sensor and timer lights that come on at night often show it up.
It only trips in wind and rain
Rain blown sideways reaches fittings that normally stay dry, like lights under the eaves or a power point on an exposed wall.
Water stains near a light or fan
Brown marks on the ceiling around a downlight or fan mean water is reaching it from the roof. Switch the lights off at the board and call.
How we find it and keep it dry
We test the circuits first, then go straight to the fittings on the one that's leaking.
- 1
Talk it through on the phone
Lachie asks which switch trips, how soon after rain, and what's outside: lights, power points, a pool, a shed. Photos of your outdoor fittings help.
- 2
Test while it's wet
At the board, he tests the insulation on each circuit. A wet fault shows up clearly, which is why we try to come during or soon after rain. A dried-out fault can test clean.
- 3
Find the wet fitting
On the faulty circuit, he checks each outdoor fitting, power point and appliance, and looks for water in the roof. Water marks, rust and green corrosion show where it got in.
- 4
Fix it so it stays dry
We replace the damaged fitting with a properly weatherproof one, or repair or re-run the cable in conduit. Then we test the circuit and the safety switch. You get a Certificate of Compliance for Electrical Work (CCEW) where the work needs one.
Replace the fitting, move it, or re-run the cable: your options side by side
Once we know where the water's getting in, the fix is usually one fitting.
Drying out isn't a fix. A fitting that has let water in will do it again, and while it's wet it can be live to touch.
What you can safely do now
Water and power together are dangerous. Keep it simple and stay away from anything wet.
Safe to do now
- Reset the safety switch once. If it trips again, leave it off.
- Keep everyone, kids and pets included, away from wet outdoor fittings and pool gear.
- Unplug outdoor appliances and extension leads, but only if the plug and your hands are dry and you're not standing in water.
- Note how soon after rain it trips, and take a photo of the switchboard.
- From a safe distance, photograph any outdoor light or power point that looks cracked, open or full of water.
Don't
- Don't touch a wet outdoor fitting, or the switchboard if it's wet.
- Don't use outdoor power points, extension leads or power tools while it's wet or tripping.
- Don't open a light or power point to drain or dry it. It can be live.
- Don't keep resetting the switch to get through the storm.
Call straight away if
- Water is dripping from a light, fan or ceiling. Keep clear, and switch off the main switch only if you can reach it without touching anything wet.
- You feel a tingle or shock from a tap, the shower or anything metal outside. Keep everyone away and call Ausgrid on 13 13 88 first.
- Power lines are down or sparking in the storm. Stay well back and call Ausgrid on 13 13 88, or 000 if anyone is hurt.
- There's smoke, sparking or a burning smell. If there's fire, call 000 and never put water on it.
Questions people ask
Why does my safety switch trip when it rains?
Water is getting into something electrical, usually an outdoor power point, a garden or sensor light, pool gear, or a fitting under a leaking roof. Wet wiring leaks power to earth, and the safety switch cuts it to protect you.
Why does it work again once it dries out?
Because the water's gone, not the fault. The cracked seal, open lid or damaged cable is still there, and the next heavy rain will trip it again. Testing soon after rain is the quickest way to find it.
Is it dangerous?
It can be. While a fitting is wet, its metal parts can become live. The safety switch is protecting you by cutting the power. Keep away from wet fittings, don't use outdoor power while it's tripping, and get it found.
Can a leaking roof trip the safety switch?
Yes. Water running through the roof can drip onto junction boxes, downlights and cables. If you see stains around a light or fan, switch the lights off at the switchboard if it's dry and safe to reach, and call us.
What is a weatherproof power point?
One built for outdoors, with a sealed body and a lid that closes over the plug. They're rated for how well they keep out dust and water. The lid only works when it's shut, so close it when nothing's plugged in.
Can you come while it's raining?
Yes, and that is often the best time. A wet fault shows up clearly on test, while a dried-out one can hide. Lachie works Monday to Friday, 7am to 5pm, and takes urgent calls from 4am to 9:30pm, 7 days across Newcastle & Lake Macquarie. Call 0402 079 953.

Get a free quote from Lachie
Four quick details and Lachie will be in touch. Your quote is back within 24 hours, with no hidden fees.
- Free quotes. Back to you within 24 hours, in plain English, with no hidden fees.
- Upfront pricing. You know the cost before any work starts.
- 100% satisfaction guarantee. Not happy with the work? Lachie comes back and makes it right, free.
- Quality guarantee. Every job done to the Australian wiring rules (AS/NZS 3000), with parts that meet Australian standards, and tested before we leave.
Rather talk it through? Call Lachie on 0402 079 953