Available nowNewcastle, Lake Macquarie & the Hunter · Urgent calls 4am–9:30pm, 7 days

Urgent? Call Lachie now

Burning smell at the switchboard or meter box? Stay clear and call us now

A smell at the board means a connection is overheating. Smoke, sparks or flames: get out and call 000. Otherwise, stay clear and call us now.

5.0 from 24 Google reviewsUpfront pricesLicensed & insured

Brick meter box with smart meters and a switchboard, door open

Offers on this job

  • $0Call-out feeOn booked jobs, Monday to Friday, 7am to 5pm.
  • $200 offSwitchboard upgradeOld fuses or no safety switches? Save on a new switchboard.
  • $60 offYour first jobNew customers save on their first booked job.

The $0 call-out is for booked jobs: a time we have set together, with the work going ahead. It applies Monday to Friday, 7am to 5pm. After-hours emergency call-outs have a minimum charge of $349 + GST, and Lachie confirms it on the phone before he drives out.

What usually causes it

A switchboard carries every bit of power in the house. A poor connection anywhere in it gets hot, and the main connections carry the most.

  • A loose connection on a breaker or the main switch Most common

    Terminals warm up and cool down every day. Over the years, screws loosen and joints corrode. A poor joint resists the current, heats up and loosens further. The main switch carries the whole house, so heat there builds fast.

  • Old ceramic fuses Older homes

    Rewireable fuses sit in ceramic holders with spring contacts. As the contacts lose their grip, or the wrong fuse wire is fitted, the holder runs hot and can scorch the board behind it.

  • A failing breaker or safety switch

    Breakers and safety switches wear out. A failing one can overheat inside its case, even on a normal load, and the plastic around it scorches.

  • Heavy new loads on an old board

    Air con, an induction cooktop, a pool pump or an EV charger added to an older board can push circuits and the main switch harder than they were built for.

  • The meter or the incoming supply

    The cables between Ausgrid's supply, the service fuse and the meter carry everything. A loose terminal there smells the same, but it's Ausgrid or Level 2 accredited service provider work.

  • Water, insects or vermin in the box Less common

    Water through a damaged meter box door, an ant or wasp nest, or mice in the box can bridge connections and cause arcing and burning.

What you might notice at the board

Any of these at the switchboard or meter box means heat where it shouldn't be. Look from a distance and don't touch anything.

  • A hot plastic or burning smell

    Strongest when the meter box door is open, or noticeable outside near the box. It often comes and goes as the house uses more or less power.

  • Brown or black marks

    Discolouring around a breaker, the main switch, a fuse holder or the meter terminals means arcing or heat has already happened there.

  • Crackling, sizzling or a loud buzz

    A connection that's arcing under load can crackle, sizzle or buzz. Any of those sounds alongside a smell means it's getting worse.

  • Melted or warped plastic

    A breaker, fuse holder or cover that has softened, bubbled or changed shape has been very hot.

  • Lights flickering or dimming

    If lights through the house flicker or dim as well, the loose connection may be on the main switch or the supply into the board.

  • Power going off and on

    A connection that's burning through can drop power to the whole house, or one part of it, then bring it back. That's a sign it's getting worse.

How we make it safe and fix it

We make it safe, find the hot connection, then repair or replace what's been damaged.

  1. 1

    Make it safe

    Lachie looks before touching anything. Where it's needed, he isolates the board, then checks every connection for heat and damage. If the fault is on Ausgrid's side, he tells you and helps you report it.

  2. 2

    Find the hot connection

    We look for scorching, check each breaker and the main switch, and test the terminals and neutral connections. A burnt joint is usually easy to spot once the cover is off.

  3. 3

    Repair what we can, price what we can't

    Burnt cable ends are cut back to clean copper and remade, and damaged breakers or switches are replaced. If the board itself is heat-damaged or unsafe, we explain why and price a new one. You decide.

  4. 4

    Test and switch back on

    We test every circuit and safety switch before the power goes back on, and show you what we found. You get a Certificate of Compliance for Electrical Work (CCEW) where the work needs one.

Repair the connection, replace parts, or replace the board: your options side by side

The right fix depends on how much heat damage there is and how old the board is.

Repair the burnt connection

One loose or scorched terminal on a board in good condition

  • Often done on the first visit, with the power back on the same day.
  • If the other connections are the same age, they may need attention later.
  • For good, once the joint is remade and tested.

Replace the damaged breakers or main switch

A failing breaker, safety switch or main switch on an otherwise sound board

  • Fixes the hot part without replacing the whole board.
  • Older boards can need parts that are hard to match, or have no room to add safety switches.
  • Many years.

Replace the switchboard

Heat-damaged boards, old ceramic fuses, no safety switches, or an old backing board

  • Every connection new, every circuit protected and labelled, with room for air con, solar or an EV charger later.
  • The biggest job. Work at the meter or service fuse is Ausgrid or Level 2 work.
  • A new board built to current wiring rules.

A burnt connection doesn't automatically mean a new switchboard. Older meter boards can contain asbestos, and if yours is damaged it's handled to SafeWork NSW rules. Lachie tells you what he found and prices each option. The choice is yours.

What you can safely do now

Your safety comes before the power. Keep away from the board unless it's clearly safe.

Safe to do now

  • If there's smoke, sparks or flames, get everyone out, close the doors behind you and call 000.
  • If the smell is faint, the board is dry, and there's no smoke, sparking, buzzing or scorching, you can switch off the main switch. If you're unsure, leave it.
  • Keep everyone, especially kids and pets, well away from the meter box.
  • If the power is still on, switch off heaters, air con and other heavy appliances to take the load off the board.
  • From a safe distance, take a photo of the board and note what you smelt, saw and heard.
  • Call Lachie on 0402 079 953.

Don't

  • Never put water on an electrical fire or a smoking switchboard.
  • Don't touch the board if it's wet, hot, scorched, smoking or buzzing.
  • Don't take the switchboard cover off, pull fuses or try to tighten anything.
  • Don't touch the meter, the service fuse or the cables coming into the box. They stay live even with your main switch off.
  • Don't switch the power back on because the smell has faded.

Call straight away if

  • You can smell burning at the board or meter box, even faintly.
  • There are scorch marks, melted plastic or crackling at the board.
  • Lights are flickering or dimming through the house, or the power is dropping in and out.
  • You feel a tingle from a tap or the shower. Keep away from it and call Ausgrid on 13 13 88 first.
Call Lachie

What locals say

5.0 from 24 Google reviewsWord for word, nothing edited.

  • We have had Lachie from Cazlec do a lot of work on our home in Merewether. He has always been honest and reliable and we know he will enjoy many years of success.

    todd blatchford, Merewether Google review

  • I've used Lachie @ Cazlec on several occasions now and highly recommend. He does a great job, is reliable, on time, and always leaves everything clean and tidy. Pricing is very fair as well.

    Doug Norton Google review

  • We have the pleasure of working with Lachie and his team at Clarke & Co Property Management for both emergency call-outs and general maintenance work. Lachie is always quick to respond, professional, and happy to help whenever needed. His communication and workmanship are consistently excellent.

    Calais Horrigan Google review

  • Cazlec (Lachlan) did a thorough and tidy job for a very reasonable price. Prompt and professional, I'll happily refer him to others. Thanks!

    Samuel Roberts Google review

  • We've been using Cazlec Electrical for our business and have always been impressed with the quality of service. They arrive when they say they will, and take the time to explain any issues and solutions clearly.

    Bobby Google review

  • Lachlan and his team have been extremely prompt when we have needed an electrician. They are professional and personable and would highly recommend them. No job too small.

    Marie Smith Google review

  • We have used Cazlec Electrical on a number of occasions and have always had a quick response and have been extremely pleased with the work they have done. I would highly recommend this company.

    Terence Coombes Google review

  • I have been using Cazlec Electrical for the last 3 years. Always on time. No hassle and gets the job done. Highly recommend.

    steven thomas Google review

  • Professional and outstanding tradesmen.

    Rob Iacopetta Google review

  • Highly recommend. Great service!

    Sharyn Rogers Google review

More reviews

Questions people ask

Why does my switchboard smell like burning?

A connection in it is overheating. Usually it's a loose terminal on a breaker or the main switch, a failing breaker, or an old ceramic fuse holder. It's a fire risk. Stay clear, switch off the main switch only if it's clearly safe, and call.

Is a burning smell from the meter box an emergency?

Yes. The switchboard carries all the power in the house, and a hot connection there can start a fire. If there is smoke or flames, call 000. Otherwise, stay clear and call us now.

Who fixes the meter box, Ausgrid or an electrician?

It depends where the heat is. Your switchboard, breakers and wiring are a licensed electrician's job. The service fuse, meter and incoming mains are Ausgrid or Level 2 work. Lachie finds where the fault is and tells you who fixes it.

Can a switchboard catch fire?

Yes. Loose connections, overloaded circuits and old fuse holders can get hot enough to burn the board and the wiring behind it. That's why heat, a smell or scorch marks at the board need checking straight away.

Do I need a new switchboard after a burning smell?

Not always. One burnt connection on a sound board is often repaired. If the board is heat-damaged, has ceramic fuses or no safety switches, a new board is usually the safer fix. Lachie prices both, and you decide.

Can you come tonight?

Yes. Lachie takes urgent calls from 4am to 9:30pm, 7 days. Call 0402 079 953 and tell us what you can smell, see and hear. If there's any smoke, get everyone out and call 000 first. Stay clear of the board while you wait.

Lachie

Get a free quote from Lachie

Four quick details and Lachie will be in touch. Your quote is back within 24 hours, with no hidden fees.

  • Free quotes. Back to you within 24 hours, in plain English, with no hidden fees.
  • Upfront pricing. You know the cost before any work starts.
  • 100% satisfaction guarantee. Not happy with the work? Lachie comes back and makes it right, free.
  • Quality guarantee. Every job done to the Australian wiring rules (AS/NZS 3000), with parts that meet Australian standards, and tested before we leave.

Rather talk it through? Call Lachie on 0402 079 953

We use your details only to quote and book this job. Privacy.