Available nowNewcastle, Lake Macquarie & the Hunter · Urgent calls 4am–9:30pm, 7 days

Not an emergency, but don't leave it

Light globes keep blowing? We'll find the fault in the fitting or the voltage

Usually it's the fitting: a worn lampholder, heat or vibration. If globes blow all over the house, the voltage may be running high. Lachie tests both and fixes it.

5.0 from 24 Google reviewsUpfront pricesLicensed & insured

Chandelier, wall light and under-cabinet lighting in a kitchen and dining room

Offers on this job

  • $0Call-out feeOn booked jobs, Monday to Friday, 7am to 5pm.
  • $60 offYour first jobNew customers save on their first booked job.

The $0 call-out is for booked jobs: a time we have set together, with the work going ahead. It applies Monday to Friday, 7am to 5pm. After-hours emergency call-outs have a minimum charge of $349 + GST, and Lachie confirms it on the phone before he drives out.

Why the same light keeps blowing globes

A globe that blows again and again is a sign of a fault in the fitting, a mismatch with the globe or switch, or a supply problem. Where it happens points to which.

A light fitting with a blown globe and the things that cause itA ceiling with an enclosed glass light fitting. Inside, the lampholder is sparking and the globe is blackened and blown, with heat trapped under the glass. A dimmer switch is on the wall and the supply cable in the roof has a meter reading high. Supply Dimmer Enclosed light 12345
What the numbers show
  1. A worn or burnt lampholder
  2. Heat trapped in the fitting
  3. The wrong globe
  4. A dimmer that doesn't match
  5. The supply voltage
What you're looking at: A closed glass light fitting on the ceiling. Inside, the globe has blackened and blown, the holder it screws into is sparking, and heat is trapped under the glass. There's a dimmer on the wall, and the meter on the cable shows the supply voltage running high.Simplified drawing. Red shows the fault or a switch that has tripped. Every property is different: Lachie will show you what's going on at yours.
  1. A worn or burnt lampholder

    The contacts that hold the globe weaken with heat and arc while the light is on, burning the globe's base. New globes in a damaged lampholder fail fast.

  2. Heat trapped in the fitting

    Enclosed fittings like oyster lights and glass shades hold heat. A globe that's too powerful, or an LED not rated for enclosed fittings, cooks itself.

  3. The wrong globe

    The fitting's label shows the largest globe it takes. Old-style globes near a ceiling fan or slamming door also shake their filaments loose.

  4. A dimmer that doesn't match

    A dimmer that doesn't suit the globe stresses it and shortens its life. LEDs need a dimmer made for them, or a dimmable LED.

  5. The supply voltage

    If globes blow all over the house, we measure the supply. A high supply is Ausgrid's to fix and we help you report it. A tingle from a tap as well? Call 13 13 88.

What usually causes it: more detail on each cause

Globes are meant to last for years. When they don't, something in the fitting or the supply is cutting their life short.

  • A worn or burnt lampholder Most common

    The springs and contacts that hold the globe weaken with heat. A loose contact arcs while the light is on, burning the globe's base and the lampholder. New globes in a damaged lampholder fail fast.

  • Too much heat in the fitting

    Enclosed fittings like oyster lights and glass shades trap heat. A globe that's too powerful, or an LED not rated for enclosed fittings, cooks itself. The fitting's label shows the largest globe it takes.

  • Vibration

    Old-style incandescent and halogen globes have a thin filament that shakes loose. Ceiling fans, slamming doors and rangehood motors all do it. LEDs cope with vibration far better.

  • The supply voltage running high Whole house

    Globes, old-style ones especially, wear out faster on a supply that sits at the top of the allowed range. If globes blow all over the house, we measure it. A high supply is Ausgrid's to look at, and we help you report it.

  • A loose main connection or failing neutral Call now

    A poor neutral connection makes the voltage swing, so some lights glow brighter while others dim, and globes blow. If a tap or appliance also gives you a tingle, call Ausgrid on 13 13 88 first.

  • A worn rangehood or oven lampholder Kitchen

    The lampholder inside a rangehood or oven lives in heat and grease and breaks down over time. That's part of the appliance, so it's a job for the maker's service agent. We don't repair rangehoods or ovens, but we can install a new one.

Where and how they blow tells us where to look

Note which lights go through globes, and how often. One fitting and the whole house point to different faults.

  • The same light, over and over

    If one fitting eats globes while the rest are fine, the fault is in that fitting: its lampholder, its connections or the heat it runs at.

  • Globes blowing all over the house

    If globes fail early in every room, look at what they share: the supply voltage, or a loose connection at the switchboard.

  • It blows the moment you switch it on

    Old-style globes are most likely to fail at switch-on. If it happens often in one light, a connection or the switch may be arcing.

  • The rangehood or oven light

    These run in heat, steam and grease, and the rangehood fan shakes them. They need a heat-rated globe. If the right globes keep failing, the lampholder inside the appliance has broken down.

  • A light near a door or ceiling fan

    Vibration from a slamming door, a ceiling fan or footsteps on the floor above shakes the thin filament in old-style globes until it breaks.

  • Brown marks or a burning smell at the fitting

    Scorching on the lampholder or around the fitting means heat and arcing. Switch that circuit off at the switchboard if it's safe to reach, and call.

How we fix it

We find out why the globes are failing, so you can stop buying new ones.

  1. 1

    Ask which lights, and how often

    Lachie asks which fittings blow globes, what globes you use and how long they last. A photo of the fitting, and a blown globe if you kept it, helps.

  2. 2

    Check the fitting and lampholder

    With the circuit isolated, we take the fitting down and check the lampholder, the contacts and the connections for scorching, looseness and heat damage.

  3. 3

    Measure the voltage

    If globes blow across the house, we measure the supply at the switchboard and check the main connections. The readings show whether it's your wiring or Ausgrid's supply.

  4. 4

    Fix it and fit the right globe

    We remake loose connections, or replace the fitting with a new one and take the old one away, and fit a globe rated for that fitting. You get the price before any work starts, and a Certificate of Compliance for Electrical Work (CCEW) where the work needs one.

Fix the connections, replace the fitting, or change to LED: your options side by side

Most of the time it's one fitting. You get the price for each option before any work starts.

Fix the wiring and connections

A sound fitting with a loose connection at the fitting or the switch

  • Keeps the fitting you like and stops it eating globes.
  • We don't repair fittings, so a worn or burnt lampholder means a new fitting.
  • Many years.

Replace the fitting

Old, heat-damaged or enclosed fittings that cook globes

  • A new fitting made for LEDs, with room for the heat to escape. Buy it through us and we pass on our trade discount.
  • You'll be choosing a new look for that spot.
  • Usually many years.

Change to LED fittings

Rooms where several lights blow globes, or old halogen downlights

  • LEDs run cooler, handle vibration better and last far longer than old-style globes.
  • A bigger job than one fitting, and dimmers may need changing to suit.
  • Many years. The rated life is on the box.

If globes are blowing all over the house, we check the voltage and the main connections before suggesting new fittings. Changing lights won't fix a supply problem.

What you can safely do now

Changing a globe is fine. Anything wired in is a licensed electrician's job.

Safe to do now

  • Switch the light off and let the fitting cool before you change a globe.
  • Only change globes in plug-in, bayonet or screw-in fittings, and use the type and size the fitting's label allows.
  • For a rangehood or oven light, check the manual for the heat-rated globe it needs.
  • Keep the blown globes and note roughly how long each one lasted.
  • If a fitting is scorched, buzzing or smells of burning, switch that circuit off at the switchboard, if it's dry and safe to reach.

Don't

  • Don't touch a fitting that's hot, damaged, scorched or wet, or one with a cracked lampholder.
  • Don't open a fitting, take one down or try to fix a lampholder. In NSW that's a licensed electrician's job.
  • Don't fit a bigger globe than the label allows, or an ordinary globe in an oven or rangehood.
  • Don't keep fitting new globes into a light that blows them. Each one is a sign of heat or arcing.

Call straight away if

  • A fitting or lampholder is scorched, buzzing, sparking or smells of burning.
  • Lights across the house go bright and dim. If a tap or appliance also gives you a tingle, call Ausgrid on 13 13 88 first.
  • A globe has broken in the fitting and the base is stuck. Switch that circuit off at the switchboard, if it's safe to reach, and leave it to us.
  • There is smoke or fire. Get everyone out and call 000. Never put water on an electrical fire.
Call Lachie

What locals say

5.0 from 24 Google reviewsWord for word, nothing edited.

  • We have had Lachie from Cazlec do a lot of work on our home in Merewether. He has always been honest and reliable and we know he will enjoy many years of success.

    todd blatchford, Merewether Google review

  • I've used Lachie @ Cazlec on several occasions now and highly recommend. He does a great job, is reliable, on time, and always leaves everything clean and tidy. Pricing is very fair as well.

    Doug Norton Google review

  • We have the pleasure of working with Lachie and his team at Clarke & Co Property Management for both emergency call-outs and general maintenance work. Lachie is always quick to respond, professional, and happy to help whenever needed. His communication and workmanship are consistently excellent.

    Calais Horrigan Google review

  • Cazlec (Lachlan) did a thorough and tidy job for a very reasonable price. Prompt and professional, I'll happily refer him to others. Thanks!

    Samuel Roberts Google review

  • We've been using Cazlec Electrical for our business and have always been impressed with the quality of service. They arrive when they say they will, and take the time to explain any issues and solutions clearly.

    Bobby Google review

  • Lachlan and his team have been extremely prompt when we have needed an electrician. They are professional and personable and would highly recommend them. No job too small.

    Marie Smith Google review

  • We have used Cazlec Electrical on a number of occasions and have always had a quick response and have been extremely pleased with the work they have done. I would highly recommend this company.

    Terence Coombes Google review

  • I have been using Cazlec Electrical for the last 3 years. Always on time. No hassle and gets the job done. Highly recommend.

    steven thomas Google review

  • Professional and outstanding tradesmen.

    Rob Iacopetta Google review

  • Highly recommend. Great service!

    Sharyn Rogers Google review

More reviews

Questions people ask

Why do my light globes keep blowing?

If it's one fitting, it's usually a worn lampholder, too much heat in an enclosed fitting, or vibration. If it's all over the house, the voltage may be high or a main connection loose. We test to find which.

Why does my stove light keep blowing?

Rangehood and oven lights run in heat, steam and grease, and the fan shakes them. They need the heat-rated globe the manual lists. If the right globe keeps failing, the lampholder inside the appliance has broken down. That's a job for the maker's service agent, or we can install a new rangehood or oven.

Can high voltage blow light globes?

Yes. Globes, especially old-style ones, wear out faster when the supply sits at the high end of the allowed range. We measure it at your switchboard. If it's high, it's Ausgrid's to look at, and we help you report it with the readings.

Is it dangerous if globes keep blowing?

It can be. A worn lampholder or loose connection arcs, and arcing makes heat. Scorch marks, buzzing or a burning smell are fire warnings. Switch that circuit off at the switchboard if it's safe to reach, and call.

Will LED globes stop them blowing?

Often, yes. LEDs handle vibration and switching better than old-style globes and last far longer. They won't fix a burnt lampholder or a high voltage, and some aren't rated for enclosed fittings or dimmers. Fix the cause first.

Can you fix it the same day?

Often, yes. Lachie works Monday to Friday, 7am to 5pm. Call 0402 079 953, tell him which light it is and how often it blows, or text a photo of the fitting. You get the price before any work starts.

Lachie

Get a free quote from Lachie

Four quick details and Lachie will be in touch. Your quote is back within 24 hours, with no hidden fees.

  • Free quotes. Back to you within 24 hours, in plain English, with no hidden fees.
  • Upfront pricing. You know the cost before any work starts.
  • 100% satisfaction guarantee. Not happy with the work? Lachie comes back and makes it right, free.
  • Quality guarantee. Every job done to the Australian wiring rules (AS/NZS 3000), with parts that meet Australian standards, and tested before we leave.

Rather talk it through? Call Lachie on 0402 079 953

We use your details only to quote and book this job. Privacy.