Not an emergency, but don't leave it
Downlight not working, even with a new globe? We'll replace the driver or fitting
If a new globe didn't fix it, it's usually the driver or transformer above the ceiling, or a built-in LED that has failed. Lachie tests it and replaces what's faulty.
5.0 from 24 Google reviewsUpfront pricesLicensed & insured

Offers on this job
- $0Call-out feeOn booked jobs, Monday to Friday, 7am to 5pm.
- $60 offYour first jobNew customers save on their first booked job.
The $0 call-out is for booked jobs: a time we have set together, with the work going ahead. It applies Monday to Friday, 7am to 5pm. After-hours emergency call-outs have a minimum charge of $349 + GST, and Lachie confirms it on the phone before he drives out.
Why a downlight stops working
A downlight is more than a globe. Behind it there's a driver or transformer, connections, a switch and a circuit. Here's where we look.
- The downlight itself
- The switch or dimmer
- The driver or transformer
- A loose connection
- The circuit from the switchboard
The downlight itself
Most LED downlights are built in, with no globe to change. When the LEDs or electronics fail, the whole fitting is replaced.
The switch or dimmer
If every light on that switch is out, the switch or dimmer is a more likely cause than the downlights.
The driver or transformer
LED downlights have a driver above the ceiling, and old halogens a transformer. It's the part that fails most often, especially in a hot roof space.
A loose connection
A loose wire where the light is connected, or at a join in the roof, can cut it out or make it come and go. Burnt marks mean it has been arcing.
The circuit from the switchboard
If several lights went out at once, check the lighting circuit at the switchboard. If it's on and they're still out, the fault is in the circuit.
What usually causes it: more detail on each cause
With the globe ruled out, it comes down to the part that powers the light, the fitting itself, or the wiring.
A failed driver or transformer Most common
Drivers and transformers sit in the roof space, where summer heat wears them out, and cheap ones fail first. Once one goes, the light is dead or cuts in and out, whatever globe is in it.
A built-in LED at the end of its life
Most LED downlights fitted in recent years are sealed units, with the LEDs and driver sold together. When one fails, the fitting is replaced. There's no globe to change.
A burnt lampholder or connection
In downlights that take a globe, the lampholder can scorch from heat and poor contact, so a good globe never lights. A burnt connection above the ceiling does the same.
Overheating under insulation
Downlights not rated to be covered by insulation overheat if it's pushed over them, and some switch off when hot. Halogens close to insulation are a fire risk.
A loose connection in the roof Fire risk
A wire that has worked loose at a join in the roof can kill one light or a run of them. If it's arcing, it's making heat, so burnt marks or a smell need fixing soon.
Old halogens failing one by one Older homes
If the house still has halogen downlights, the transformers are likely all the same age. One dying is often the first of several. That's when changing the room to LED downlights makes sense.
What the dead downlight is telling you
How it failed, and whether it's on its own, points to the part to check.
One downlight out, the rest fine
When only one light is dead and a new globe didn't help, it's usually that light's driver, transformer or fitting.
It cuts out, then comes back
A downlight that goes off after a while and returns once it cools has a failing driver, or is overheating and switching itself off.
A whole row went out at once
That's the switch, the dimmer, a join they share in the roof, or the lighting circuit. Check the switchboard first.
A new globe works for a day, then dies
The fitting is killing globes. That usually means a failing transformer, a burnt lampholder or a poor connection.
A burning smell or brown marks
Scorching on the trim or the ceiling around the light means real heat. Switch that circuit off at the switchboard if it's safe to reach, and call.
How we fix it
We test before we replace, so you only pay for the part that's actually failed.
- 1
Ask what happened
Lachie asks whether it's one light or a row, and whether it flickered or cut out first. A photo of the light and its trim helps.
- 2
Check power reaches the light
At the switchboard and the switch, we check the lighting circuit and test that power is getting through. If it isn't, the fault is in the switch or the circuit, and we follow it from there.
- 3
Lower the downlight and test the driver
With the circuit isolated, we lower the downlight on its lead and check the driver or transformer, the lampholder and the connections. A failed driver shows up quickly once tested.
- 4
Replace it and match the rest
We replace the driver, or the whole fitting if it's a sealed LED, matching the colour and size of your other lights as closely as we can. You get the price first, and a Certificate of Compliance for Electrical Work (CCEW) where the work needs one.
Replace the driver, the fitting or the room: your options side by side
What we find decides the fix. Most single dead downlights need just one part.
If one downlight has failed and the others are new, we replace that one. If they're all the same age and starting to go, we'll say so, and you decide. Buy the lights through us and we pass on our trade discount. We can fit lights you've bought yourself, but we can't vouch for the quality of a product when we don't know the brand or where it came from.
What you can safely do now
A dead downlight is rarely urgent. A burning smell is. These steps are safe for anyone.
Safe to do now
- Check the switchboard. If the lighting breaker or safety switch is off, reset it once. If it trips again, leave it off.
- If the downlight takes a plug-in globe, try a second new one from a different pack. Switch the light off and let it cool first.
- Try the other switches. The downlight may be switched from two places, or from a switch you don't expect.
- If there's a burning smell or brown marks around the light, switch that circuit off at the switchboard, if it's dry and safe to reach.
Don't
- Don't pull a downlight out of the ceiling, or try to replace a driver, transformer or sealed LED yourself. They're wired in, and in NSW that's a licensed electrician's job.
- Don't touch a downlight that's hot, damaged or wet.
- Don't go into the roof space to check it. There are live cables and hot fittings up there.
Call straight away if
- There is a burning smell, scorching or smoke from around a downlight.
- Water is dripping from or near a downlight. Keep clear and switch the lights off at the switchboard if you can reach it without touching anything wet.
- The lighting circuit trips straight back off when you reset it.
- There is smoke or fire. Get everyone out and call 000. Never put water on an electrical fire.
Questions people ask
Why is my downlight not working with a new globe?
Because the globe isn't the fault. It's usually the driver or transformer above the ceiling, a burnt lampholder or connection, or a sealed LED fitting that has failed. Testing shows which, so you only replace what's needed.
How do I know if it's the driver?
If power reaches the light but it stays dead, cuts out when warm, or flickered before dying, the driver is the usual suspect. We confirm it by testing, with the light lowered and the circuit isolated. You can't tell safely from below.
Can I replace a downlight myself?
No. Downlights, drivers and transformers are wired in, and in NSW only a licensed electrician can replace them. Changing a plug-in globe is fine with the light switched off and cool. If a new globe doesn't work, call us.
Why did a whole row of downlights stop working?
When several go at once, the fault is in what they share: the switch, the dimmer, a join in the roof or the lighting circuit. Check the switchboard and reset a tripped breaker once. If they're still out, we trace it.
Should I replace all my downlights when one fails?
Not necessarily. If the others are fairly new, we replace the one. If they're old halogens, or LEDs failing one after another, doing the room at once means they all match. We tell you what we see, and you decide.
Can you fix it the same day?
Often, yes. Lachie works Monday to Friday, 7am to 5pm. Call 0402 079 953 and tell him what kind of downlight it is, or text a photo. You get the price before any work starts.

Get a free quote from Lachie
Four quick details and Lachie will be in touch. Your quote is back within 24 hours, with no hidden fees.
- Free quotes. Back to you within 24 hours, in plain English, with no hidden fees.
- Upfront pricing. You know the cost before any work starts.
- 100% satisfaction guarantee. Not happy with the work? Lachie comes back and makes it right, free.
- Quality guarantee. Every job done to the Australian wiring rules (AS/NZS 3000), with parts that meet Australian standards, and tested before we leave.
Rather talk it through? Call Lachie on 0402 079 953