Available nowNewcastle, Lake Macquarie & the Hunter · Urgent calls 4am–9:30pm, 7 days

Often fixed the same day

Light switch not working? We'll find if it's the switch, the light or the circuit

It's usually a worn switch, a failed light or driver, or a loose connection. Lachie tests all three, so you only replace what's actually faulty.

5.0 from 24 Google reviewsUpfront pricesLicensed & insured

Renovated living room with LED downlights and a timber floor

Offers on this job

  • $0Call-out feeOn booked jobs, Monday to Friday, 7am to 5pm.
  • $60 offYour first jobNew customers save on their first booked job.

The $0 call-out is for booked jobs: a time we have set together, with the work going ahead. It applies Monday to Friday, 7am to 5pm. After-hours emergency call-outs have a minimum charge of $349 + GST, and Lachie confirms it on the phone before he drives out.

Switch, light or circuit: where it's stopping

A light switch is a small mechanism with wires screwed to it. If it clicks and nothing happens, the fault is in the switch, the wiring, the light or the circuit.

Inside a light switch, from the switchboard to the lightA wall with a light switch, the cable running up through the wall and roof to a ceiling light, and the switchboard on the left. A magnified view shows the switch mechanism and its two terminals, one with a loose wire glowing and sparking. Switchboard Switch Inside the switch 12345
What the numbers show
  1. The switch mechanism
  2. A loose wire on a terminal
  3. The cable in the wall
  4. The light itself
  5. The lighting breaker
What you're looking at: A light switch on the wall, with its cable running up to the ceiling light and back to the switchboard on the left. The circle zooms inside the switch, where one wire has come loose and is sparking.Simplified drawing. Red shows the fault or a switch that has tripped. Every property is different: Lachie will show you what's going on at yours.
  1. The switch mechanism

    Springs and contacts wear after thousands of uses, so the switch stops connecting, sticks or works only sometimes. Replacing it is a quick job.

  2. A loose wire on a terminal

    A loose wire breaks the circuit or works on and off. If it's arcing, it's making heat, so a warm or buzzing switch needs fixing now.

  3. The cable in the wall

    The cable runs up the wall to the roof. A nail or screw through it, or rodent damage, can stop the light. Two-way switches add an extra cable that can fail too.

  4. The light itself

    The switch may be fine and the light dead. A failed LED driver or a worn-out sealed downlight gives exactly the same symptom.

  5. The lighting breaker

    If other lights are out too, the breaker or safety switch for the lights has tripped. Reset it once. If it trips again, leave it off and call.

What usually causes it: more detail on each cause

It can fail in three places: the switch, the light, or the circuit between them. We test each one.

  • A worn-out switch Most common

    Switches are used thousands of times. The spring and contacts inside wear, so the switch stops connecting, sticks or works only sometimes. Replacing it is a quick job.

  • A failed light, globe or driver

    The switch may be fine and the light dead. A failed LED downlight driver, or a sealed fitting that has worn out, gives exactly the same symptom.

  • A loose connection Fire risk

    A wire loose at the switch, the light or a join in the roof breaks the circuit. If it's arcing, it's making heat, which is why a warm or buzzing switch needs fixing now.

  • A tripped lighting circuit

    If the breaker or safety switch for the lights has tripped, every light on that circuit is out. That points to a fault somewhere on the lighting circuit.

  • A two-way switching fault

    Switching from two places uses extra switches and cable. A fault in either switch, or the cable between them, can leave one end dead.

  • A failed dimmer, timer or smart switch Less common

    Electronic switches have more parts to fail than a plain one. A dimmer that has overheated, or a smart switch that has lost its setup, can stop the light working.

What the switch is doing tells us where to look

How the switch feels, and what else is off, points to the switch, the light or the circuit.

  • The switch clicks but nothing happens

    If the switch feels normal, the light, its globe or driver, or the cable between them is the more likely fault.

  • The switch feels loose or soft

    A switch that doesn't click cleanly, sticks or flops has worn inside. Its contacts may no longer meet.

  • It works if you hold it a certain way

    That's worn contacts or a loose connection behind the plate. Both can arc and heat up, so stop using it.

  • Other lights are out too

    If several lights won't come on, check the lighting circuit at the switchboard. If everything on the board is on and they're still out, there is a fault on the circuit.

  • It only works from one end

    Lights switched from two places, like a hallway or stairs, rely on both switches. If one end stopped working, the fault is often in the other switch or the cable between them.

  • The switch is warm, buzzing or sparking

    That's arcing. Stop using it, switch that circuit off at the switchboard if it's safe to reach, and call.

How we fix it

We test before we replace anything, so you don't pay for a new switch when the fault is in the light.

  1. 1

    Ask what changed

    Lachie asks whether it stopped suddenly or got worse over time, whether other lights are out, and whether it's a dimmer or smart switch. A photo of the switch helps.

  2. 2

    Test the switch

    We check whether power reaches the switch and passes through it when it is on. Then, with the circuit isolated, we take the plate off and check the switch and its connections.

  3. 3

    Test the light and the circuit

    If the switch is fine, we check the light, its globe or driver, and the cable back to the switchboard. A loose join in the roof or a failed driver shows up here.

  4. 4

    Fix it and check it

    We replace the switch, the driver or the fitting, or remake the connection, then check every light on that switch works. You get the price before any work starts, and a Certificate of Compliance for Electrical Work (CCEW) where the work needs one.

Replace the switch, repair the light, or fix the circuit: your options side by side

Once we know which part failed, these are the choices. You get the price for each before any work starts.

Replace the switch

A worn, loose or sticking switch, or one that is warm or buzzing

  • Quick, usually done on the first visit, and you can choose a new style while we're there.
  • Other switches the same age may start to wear too.
  • Many years.

Repair the light

A switch that works, but a light, driver or fitting that has failed

  • Fixes the real fault without touching a good switch.
  • If the lights are old halogens, more may follow.
  • Many years, for a good-quality part.

Trace and fix the circuit

Several lights out, a tripping lighting circuit, or a loose join in the roof

  • Fixes the cause and removes a fire risk.
  • A fault that comes and goes can take longer to find.
  • For good, once the connection is remade properly.

If you've been meaning to change old switches, add a dimmer or update tired lights, we can do it on the same visit. We'll only suggest it, and the choice is yours.

What you can safely do now

These steps are safe for anyone. Anything behind the switch plate is a licensed electrician's job.

Safe to do now

  • Check the switchboard. If the lighting breaker or safety switch is off, reset it once. If it trips again, leave it off.
  • If the light takes a plug-in, bayonet or screw-in globe, try a new one. Switch it off and let the fitting cool first.
  • If the light is switched from two places, try the other switch.
  • If the switch is warm, buzzing, sparking or smells hot, stop using it and switch that circuit off at the switchboard, if it's dry and safe to reach.
  • Note when it stopped and what else is off, and take a photo of the switch.

Don't

  • Don't take the switch plate off, or try to replace a switch, dimmer or smart switch yourself. In NSW that's a licensed electrician's job.
  • Don't keep flicking or jiggling a switch that only works sometimes. Each time, the loose contact can arc.
  • Don't touch a switch that's cracked, scorched, wet or warm, or a light fitting that's hot or damaged.

Call straight away if

  • The switch is warm, buzzing, crackling, sparking or smells of burning.
  • The lighting circuit trips straight back off when you reset it.
  • You get a tingle or shock from the switch. Stop using it, switch that circuit off at the switchboard if it is safe, and call.
  • There is smoke or fire. Get everyone out and call 000. Never put water on an electrical fire.
Call Lachie

What locals say

5.0 from 24 Google reviewsWord for word, nothing edited.

  • We have had Lachie from Cazlec do a lot of work on our home in Merewether. He has always been honest and reliable and we know he will enjoy many years of success.

    todd blatchford, Merewether Google review

  • I've used Lachie @ Cazlec on several occasions now and highly recommend. He does a great job, is reliable, on time, and always leaves everything clean and tidy. Pricing is very fair as well.

    Doug Norton Google review

  • We have the pleasure of working with Lachie and his team at Clarke & Co Property Management for both emergency call-outs and general maintenance work. Lachie is always quick to respond, professional, and happy to help whenever needed. His communication and workmanship are consistently excellent.

    Calais Horrigan Google review

  • Cazlec (Lachlan) did a thorough and tidy job for a very reasonable price. Prompt and professional, I'll happily refer him to others. Thanks!

    Samuel Roberts Google review

  • We've been using Cazlec Electrical for our business and have always been impressed with the quality of service. They arrive when they say they will, and take the time to explain any issues and solutions clearly.

    Bobby Google review

  • Lachlan and his team have been extremely prompt when we have needed an electrician. They are professional and personable and would highly recommend them. No job too small.

    Marie Smith Google review

  • We have used Cazlec Electrical on a number of occasions and have always had a quick response and have been extremely pleased with the work they have done. I would highly recommend this company.

    Terence Coombes Google review

  • I have been using Cazlec Electrical for the last 3 years. Always on time. No hassle and gets the job done. Highly recommend.

    steven thomas Google review

  • Professional and outstanding tradesmen.

    Rob Iacopetta Google review

  • Highly recommend. Great service!

    Sharyn Rogers Google review

More reviews

Questions people ask

Why is my light switch not working?

Usually the switch has worn out, the light or its driver has failed, or a connection has worked loose. Less often, the lighting circuit has tripped. We test the switch, the light and the circuit to find which.

Why is my light switch not working when it has power?

If power reaches the switch but the light stays off, either the switch is not passing it through, or the fault is further along: the cable to the light, the driver or the light itself. Testing at each point shows where it stops.

Why won't my light switch turn on?

If it won't click on, or flops loose, the mechanism inside has worn or broken. If it clicks normally and nothing happens, the light or a loose connection is more likely. Either way, it needs testing.

Is a faulty light switch dangerous?

It can be. A worn switch or a loose connection can arc, and arcing makes heat. A switch that's warm, buzzing, sparking or only works when you jiggle it is a fire risk. Stop using it and call.

Can I replace a light switch myself?

No. In NSW, replacing a light switch is electrical wiring work, and only a licensed electrician can do it. It's a quick job for us, and we test the light and the circuit at the same time.

Can you come today?

Often, yes. Lachie works Monday to Friday, 7am to 5pm, and takes urgent calls from 4am to 9:30pm, 7 days. If the switch is sparking or hot, switch that circuit off at the switchboard if it's safe, then call 0402 079 953.

Lachie

Get a free quote from Lachie

Four quick details and Lachie will be in touch. Your quote is back within 24 hours, with no hidden fees.

  • Free quotes. Back to you within 24 hours, in plain English, with no hidden fees.
  • Upfront pricing. You know the cost before any work starts.
  • 100% satisfaction guarantee. Not happy with the work? Lachie comes back and makes it right, free.
  • Quality guarantee. Every job done to the Australian wiring rules (AS/NZS 3000), with parts that meet Australian standards, and tested before we leave.

Rather talk it through? Call Lachie on 0402 079 953

We use your details only to quote and book this job. Privacy.