Often fixed the same day
Lights not working but the power points are? We'll find the lighting fault and fix it
Lights and power points are on separate circuits. When only the lights go, a lighting breaker, safety switch, fitting or roof connection has failed. Lachie finds which and fixes it.
5.0 from 24 Google reviewsUpfront pricesLicensed & insured

Offers on this job
- $0Call-out feeOn booked jobs, Monday to Friday, 7am to 5pm.
- $60 offYour first jobNew customers save on their first booked job.
The $0 call-out is for booked jobs: a time we have set together, with the work going ahead. It applies Monday to Friday, 7am to 5pm. After-hours emergency call-outs have a minimum charge of $349 + GST, and Lachie confirms it on the phone before he drives out.
Why the lights can go out while the power points still work
Your lights and power points run on separate circuits from the switchboard. When only the lights are out, the fault is on a lighting circuit: at the board, in the roof or at a fitting.
- The tripped switch for the lights
- The lighting circuit
- A failed connection in the roof
- A faulty light or driver
- The power circuit, still working
The tripped switch for the lights
A lighting breaker or the safety switch covering the lights has dropped. In older homes it may be a blown ceramic fuse. Reset it once. If it trips again, leave it off and call.
The lighting circuit
Most homes have two or three. Each runs through the roof from the board to its lights, one after another, so one fault takes out every light on it.
A failed connection in the roof
If nothing has tripped, a join at a switch, a light or a junction box has failed. Every light after it goes dark. It often flickered or buzzed first.
A faulty light or driver
A downlight driver or old halogen transformer that fails short can trip the whole circuit. If it trips when you switch on one light, leave that light off.
The power circuit, still working
Your power points are on their own circuit, so a lamp plugged in still works. It also tells us the supply to the house is fine.
What usually causes it: more detail on each cause
Lighting circuits carry less load than power circuits, so faults are usually about a connection or a fitting, not overload.
A tripped safety switch or lighting breaker Most common
A faulty fitting, water in an outdoor or bathroom light, or a shorting driver trips the switch covering the lights. In older homes, the lights may be on a ceramic fuse that has blown.
A faulty light fitting or driver
Downlights run from small drivers or transformers in the ceiling. When one fails short, it can take the whole circuit with it. Old halogen transformers are the usual suspects.
A loose connection at a switch or in the roof
Lighting circuits are joined at switches, light fittings and junction boxes in the roof. A loose or burnt joint cuts off every light after it without tripping anything.
Water or damage in the roof
A roof leak or a cracked outdoor light lets water in and trips the circuit, often after rain. Rats and possums chew cables, and roof work can crush them.
Old wiring or an old board Older homes
Brittle cable, and ceramic fuses with no safety switch on the lights, are common in older homes. We fix the fault, and if the board is part of it, we explain the options.
Which lights are out tells us where to look
Walk through the house with a torch and note which lights work. The pattern points straight at one circuit.
Every light in the house is out
Usually a tripped safety switch or lighting breaker. If nothing's off, it can be a failed connection near the board.
Lights out in one part of the house
One lighting circuit has failed. Homes are often split front and back, or upstairs and downstairs.
One room or a few lights out
A connection has failed partway along the circuit, often at a light switch or a junction box in the roof.
It trips when you switch on one light
That light, or its driver or transformer, is shorting. Leave that light switched off and reset the circuit once.
They flickered or buzzed before going out
A loose connection or a failing LED driver usually gives warning: flicker, buzzing, or a light that comes and goes.
It started after work in the roof
New downlights, insulation going in or a tradesperson in the roof can disturb an old connection or crush a cable.
How we find and fix it
We test from the switchboard out. The lighting circuit is isolated on its own, so you keep your power points while we work.
- 1
Check the board
Lachie confirms which lighting circuits are off and whether a safety switch, breaker or fuse is holding a fault.
- 2
Test the lighting circuit
With the circuit isolated, he tests the cable for shorts and leaks to earth. That tells him whether it's a fitting, a cable or a broken connection.
- 3
Find the faulty fitting or joint
He works along the circuit, checking switches, fittings, drivers and junction boxes in the roof until the fault shows up.
- 4
Fix it, test it, switch on
We remake the connection or replace the faulty fitting, driver or cable, test the circuit and check its safety switch trips as it should. You get a Certificate of Compliance for Electrical Work (CCEW) where the work needs one.
Repair the fault, swap to LEDs, or add safety switches: your options side by side
Most lighting faults are one repair. The other two are worth knowing about if the fault came from old fittings or an old board.
A lighting fault doesn't usually mean a new switchboard. If yours has ceramic fuses or no room, Lachie will tell you and price it first. You decide.
What you can safely do now
These are safe for anyone. Anything inside a light fitting, a switch or the switchboard is a licensed electrician's job.
Safe to do now
- Check the switchboard. If a safety switch or lighting breaker is off, reset it once, if the board is dry and safe to reach.
- If it trips again, leave it off. If it trips when one light goes on, leave that light switched off.
- Use lamps plugged into power points to get by. They're on a different circuit.
- Note which lights are out and when it happened, and take a photo of the switchboard.
- Keep people clear of any light that is dripping, buzzing or smells hot.
Don't
- Don't rewire or replace a ceramic fuse yourself, or put anything else in its place.
- Don't take down light fittings, open switch plates, or change drivers or transformers.
- Don't keep resetting a switch that trips straight back off.
- Don't touch a light or switch that's wet, scorched or warm.
Call straight away if
- Water is dripping from a light or the ceiling. Switch off at the main switch if you can reach it without touching anything wet.
- There's a burning smell, buzzing or scorch marks at a light, a switch or the board. If there's smoke or fire, call 000 and never put water on it.
- The whole house is dark at night and there are kids, older people or medical needs at home.
- You feel a tingle from a tap or the shower. Keep everyone clear and call Ausgrid on 13 13 88 first.
Questions people ask
Why are my lights not working but my power points are?
Lights and power points are on separate circuits. When only the lights go, a lighting breaker or safety switch has tripped, a fitting or driver has failed, or a connection has come loose. Check the board and reset once, then call.
Why did all my downlights stop working at once?
Usually the circuit they're on has tripped or lost a connection. They rarely all fail at once. A shorting driver or water in one fitting can trip the lot, and testing the circuit shows which.
Can a faulty light switch stop a whole room of lights?
Yes. If the switch or a connection behind it fails, every light it controls goes out, and sometimes the next room too if the circuit runs through it. Don't open the switch. Call us.
Is it safe to use my power points while the lights are out?
Usually, yes. They're on separate circuits. If there's a burning smell, buzzing, water or a tingle from anything, switch off at the main switch if it's safe to reach, and call us instead.
Do I need to replace all my downlights?
No. We fix the fault first. If old halogen transformers keep failing, swapping to LEDs is worth considering, and we'll price it so you can decide. It's never a condition of the repair.
Can you come today?
Often, yes. Lachie works Monday to Friday, 7am to 5pm, and takes urgent calls from 4am to 9:30pm, 7 days, so call if the whole house is dark at night. Call 0402 079 953. You get the price before any work starts.

Get a free quote from Lachie
Four quick details and Lachie will be in touch. Your quote is back within 24 hours, with no hidden fees.
- Free quotes. Back to you within 24 hours, in plain English, with no hidden fees.
- Upfront pricing. You know the cost before any work starts.
- 100% satisfaction guarantee. Not happy with the work? Lachie comes back and makes it right, free.
- Quality guarantee. Every job done to the Australian wiring rules (AS/NZS 3000), with parts that meet Australian standards, and tested before we leave.
Rather talk it through? Call Lachie on 0402 079 953