Available nowNewcastle, Lake Macquarie & the Hunter · Urgent calls 4am–9:30pm, 7 days

Urgent? Call Lachie now

No power at the meter box or main fuse blown? We'll find why and get it replaced

If the street has power and your meter box doesn't, the main fuse has likely blown. Ausgrid or a Level 2 electrician replaces it. We find why it blew.

5.0 from 24 Google reviewsUpfront pricesLicensed & insured

Brick meter box with the door open, showing smart meters and a switchboard

Offers on this job

  • $0Call-out feeOn booked jobs, Monday to Friday, 7am to 5pm.
  • $200 offSwitchboard upgradeOld fuses or no safety switches? Save on a new switchboard.
  • $60 offYour first jobNew customers save on their first booked job.

The $0 call-out is for booked jobs: a time we have set together, with the work going ahead. It applies Monday to Friday, 7am to 5pm. After-hours emergency call-outs have a minimum charge of $349 + GST, and Lachie confirms it on the phone before he drives out.

Where the main fuse sits, and why the house goes dark

Power comes along Ausgrid's service line, through the main (service) fuse, then the meter and your main switch. If the fuse blows, nothing after it gets power.

A blown main fuse in the meter box cutting power to the houseA close-up of the outside wall. The service line comes from the network pole to a bracket under the eave, and the cable runs down into the meter box. Inside the box the service fuse has blown, the meter screen is blank and the main switch sits below. The house window is dark. Ausgrid poleMeter boxNo power 12345
What the numbers show
  1. The service line (Ausgrid's)
  2. The point of attachment
  3. The main (service) fuse
  4. The meter
  5. The main switch
What you're looking at: The outside wall of your house. The power line comes from the street pole to a bracket under the eave, then down into the meter box. Inside the box, the main fuse has blown (in red), so the meter screen is blank and the house is dark.Simplified drawing. Red shows the fault or a switch that has tripped. Every property is different: Lachie will show you what's going on at yours.
  1. The service line (Ausgrid's)

    The line from the pole to your house. If the neighbours and streetlights are out too, it's an outage, not your fuse. Check Ausgrid's outage map or call 13 13 88.

  2. The point of attachment

    The bracket where the line meets your house. A branch on the line, a storm or a loose connection here can blow the fuse or cut the supply. Keep clear of a damaged line.

  3. The main (service) fuse

    Sealed in the meter box, between Ausgrid's line and your meter. A short, a storm or a worn fuse holder can blow it. Only Ausgrid or a Level 2 accredited electrician can replace it.

  4. The meter

    A blank meter screen with every switch on points to the fuse or the supply before it. In a three-phase home, one blown fuse takes out only part of the house.

  5. The main switch

    Check it's on first: a tripped main switch can look like a dead supply. Reset it once only. A short in the house must be found, or a new fuse can blow again.

Why main fuses blow: more detail on each cause

A main fuse blows to protect the cable between the street and your switchboard. Something made it work too hard.

  • A short circuit in the house

    A fault in the main cable, the switchboard or a big appliance can draw a huge current in a split second. If the board's own protection doesn't clear it first, the main fuse goes.

  • Storm damage and lightning After storms

    A strike nearby, a branch on the line or water in the meter box can blow the fuse, even with nothing wrong inside the house.

  • Too much load on a small supply

    Many older homes were connected for far less than we use now. Air con, the oven, a dryer and an EV charger on at once, on a hot day, can overload it.

  • An old fuse or a worn fuse holder Older homes

    Fuse holders heat up at loose or corroded contacts, and old fuses can weaken with age. They can fail with no fault anywhere else.

How to tell if the main fuse has gone

Look, don't touch. The meter box tells you a lot with the door open.

  • The whole house is out, the street is not

    Neighbours and streetlights on, your house dark, and the main switch is on. That points to your main fuse or the line to your house.

  • The meter's screen is blank

    If the screen is blank, power isn't reaching the meter, which usually means the main fuse or the supply. On an older meter, the disc stops turning.

  • There was a bang, a flash or a smell

    A bang or flash at the meter box as the power went, or a smell of hot plastic, means a fault blew the fuse. Keep clear and call.

  • Part of the house is out, in a three-phase home

    Three-phase homes have a main fuse for each phase. If one blows, only the circuits on that phase go off.

How we get you back on

Replacing the fuse is only half the job. If we don't find why it blew, it can blow again.

  1. 1

    Rule out an outage

    Lachie asks what the neighbours have, what the meter shows and what happened when it went. If it sounds like an Ausgrid outage or a line down, he'll tell you to call 13 13 88.

  2. 2

    Test at the meter box

    He tests the supply coming in, then the main switch, the main cable and the switchboard, to find the fault before anything is switched back on.

  3. 3

    Fix what blew it

    A shorted cable, a burnt connection or a faulty appliance is repaired or isolated. If the board itself is the problem, we make it safe and explain the options.

  4. 4

    Replace the fuse and switch back on

    Replacing the sealed main fuse is Ausgrid or Level 2 accredited service provider work. Once it's in, we switch on circuit by circuit and test as we go. You get a Certificate of Compliance for Electrical Work (CCEW) where the work needs one.

Replace the fuse, replace the holder, or upgrade: your options side by side

It depends on why it blew and the age of your meter box. You get the price before any work starts.

Find the fault and replace the fuse

A one-off blow from a storm, a short or a faulty appliance

  • Gets you back on once the cause is fixed.
  • If the fuse holder or main switch is old or heat-damaged, it can happen again.
  • For good, once the cause is fixed.

Replace a worn fuse holder

Holders with heat marks, cracks or loose contacts

  • Removes a common weak point without replacing the whole board.
  • The holder is on the supply side, so it's Ausgrid or Level 2 work and may need booking.
  • Many years.

Upgrade the switchboard and supply

Old fuse boards, a supply too small for what you run now, or plans for solar or an EV charger

  • New protection on every circuit, and a supply sized for how you live now.
  • A bigger job, usually booked once the power is safely back on. Mains work involves Ausgrid.
  • Many years, built to the current wiring rules.

Ausgrid owns the street network. The main fuse, the mains and the meter are Ausgrid or Level 2 accredited service provider work. Your switchboard and wiring are a licensed electrician's job. We tell you which is which before anything is done.

What you can safely do now

Check from the outside in, and stop at anything wet, burnt or damaged.

Safe to do now

  • Look outside. If the neighbours and streetlights are out too, it's an outage. Check Ausgrid's outage map or call 13 13 88.
  • Open the meter box door and look, without touching anything inside. Is the meter's screen blank? Is the main switch on?
  • If the main switch is off, switch it on once, as long as the board is dry and undamaged. If it goes straight off, leave it.
  • Turn off the oven, heaters and air con at their own switches, so they don't all start at once when power returns.

Don't

  • Don't touch, pull out or replace the main fuse. It's sealed, and it's live on Ausgrid's side even when your house is off.
  • Don't touch the meter box if it's wet, scorched, buzzing or smells hot.
  • Don't connect a generator to your house wiring or a power point. It can feed power back into the street lines.

Call straight away if

  • There was a bang, a flash or a burning smell at the meter box. Keep clear, and call 000 if there's smoke or fire. Never put water on it.
  • A line to the house is down or sagging: stay well back and call Ausgrid on 13 13 88.
  • Lights flare and dim, or you feel a tingle from a tap or the shower: call Ausgrid on 13 13 88, then us.
  • The street has power, your main switch is on, and your house still has none.
Call Lachie

What locals say

5.0 from 24 Google reviewsWord for word, nothing edited.

  • We have had Lachie from Cazlec do a lot of work on our home in Merewether. He has always been honest and reliable and we know he will enjoy many years of success.

    todd blatchford, Merewether Google review

  • I've used Lachie @ Cazlec on several occasions now and highly recommend. He does a great job, is reliable, on time, and always leaves everything clean and tidy. Pricing is very fair as well.

    Doug Norton Google review

  • We have the pleasure of working with Lachie and his team at Clarke & Co Property Management for both emergency call-outs and general maintenance work. Lachie is always quick to respond, professional, and happy to help whenever needed. His communication and workmanship are consistently excellent.

    Calais Horrigan Google review

  • Cazlec (Lachlan) did a thorough and tidy job for a very reasonable price. Prompt and professional, I'll happily refer him to others. Thanks!

    Samuel Roberts Google review

  • We've been using Cazlec Electrical for our business and have always been impressed with the quality of service. They arrive when they say they will, and take the time to explain any issues and solutions clearly.

    Bobby Google review

  • Lachlan and his team have been extremely prompt when we have needed an electrician. They are professional and personable and would highly recommend them. No job too small.

    Marie Smith Google review

  • We have used Cazlec Electrical on a number of occasions and have always had a quick response and have been extremely pleased with the work they have done. I would highly recommend this company.

    Terence Coombes Google review

  • I have been using Cazlec Electrical for the last 3 years. Always on time. No hassle and gets the job done. Highly recommend.

    steven thomas Google review

  • Professional and outstanding tradesmen.

    Rob Iacopetta Google review

  • Highly recommend. Great service!

    Sharyn Rogers Google review

More reviews

Questions people ask

What does a blown main fuse mean?

The fuse between Ausgrid's line and your meter has cut the supply to protect the cable into your house. Something made it work too hard: a short, a storm, too much load or a worn holder.

Can I replace the main fuse myself?

No. It's sealed, it's live on the street side, and replacing it is Ausgrid or Level 2 accredited service provider work. In NSW, electrical work must be done by someone licensed to do it.

Is the main fuse the same as the main switch?

No. The main switch is part of your switchboard and turns the whole house off. The main fuse, or service fuse, sits before the meter and is sealed. Main switch on and meter screen blank? Suspect the fuse or the supply.

Who do I call, Ausgrid or an electrician?

If the street is out or a line is down, call Ausgrid on 13 13 88. If only your house is out, call us. We find why it blew, and tell you who replaces the fuse.

Why does my main fuse keep blowing?

Something keeps overloading or shorting it: a faulty appliance, a damaged cable, a worn fuse holder, or more load than your supply was built for. A new fuse won't fix that. We test until we find it.

Can you come tonight?

Yes. Lachie takes urgent calls from 4am to 9:30pm, 7 days, and works Monday to Friday, 7am to 5pm. If it's an Ausgrid outage, he'll tell you on the phone. You get the price before any work starts.

Lachie

Get a free quote from Lachie

Four quick details and Lachie will be in touch. Your quote is back within 24 hours, with no hidden fees.

  • Free quotes. Back to you within 24 hours, in plain English, with no hidden fees.
  • Upfront pricing. You know the cost before any work starts.
  • 100% satisfaction guarantee. Not happy with the work? Lachie comes back and makes it right, free.
  • Quality guarantee. Every job done to the Australian wiring rules (AS/NZS 3000), with parts that meet Australian standards, and tested before we leave.

Rather talk it through? Call Lachie on 0402 079 953

We use your details only to quote and book this job. Privacy.