Urgent? Call Lachie now
Got a shock from a light switch or power point? Stop using it, we'll make it safe
Stop using it. Switch that circuit off at the switchboard if it's dry and safe to reach. If anyone is hurt, call 000. Then call us.
5.0 from 24 Google reviewsUpfront pricesLicensed & insured

Offers on this job
- $0Call-out feeOn booked jobs, Monday to Friday, 7am to 5pm.
- $60 offYour first jobNew customers save on their first booked job.
The $0 call-out is for booked jobs: a time we have set together, with the work going ahead. It applies Monday to Friday, 7am to 5pm. After-hours emergency call-outs have a minimum charge of $349 + GST, and Lachie confirms it on the phone before he drives out.
Why a power point or switch can give you a shock
A power point or switch should never give you a shock. When it does, it's usually one of these, and often more than one.
- A cracked plate
- A worn plug or cord
- A faulty appliance
- A broken earth behind the plate
- No safety switch on the circuit
A cracked plate
A knock or age can crack a power point or switch plate and leave a live part close enough to touch.
A worn plug or cord
A cracked plug or a frayed cord can bare live metal right where you hold it, so the shock seems to come from the wall.
A faulty appliance
A fault inside a toaster, kettle or metal lamp can make its case live. If that's where you felt it, stop using it.
A broken earth behind the plate
The earth gives a fault a safe path back to the board. If a wire behind the plate is loose or broken, metal parts can stay live instead of tripping.
No safety switch on the circuit
A safety switch (RCD) cuts the power fast if current leaks through a person. Many older boards have them on only some circuits, or none.
What usually causes it: more detail on each cause
A switch or power point should never give you a shock. When it does, it is usually one of these.
A cracked or broken plate Common
A knock, or age, can crack a switch or power point plate and leave a live part close enough to touch. It's easy to miss, especially on an older switch.
A loose or damaged wire behind the plate
A wire that has come loose can touch a metal mounting plate or screw. If the earth isn't working, that metal can become live.
Old metal switch plates Older homes
Some older homes have metal switch plates or old-style switches. If a wire behind one loosens and the plate is not properly earthed, the plate can carry a voltage.
A faulty earth
The earth gives fault current a safe path back to the switchboard. If it is broken or corroded, a fault that should trip the circuit can leave metal parts live instead.
A faulty appliance or plug
A damaged cord, a cracked plug or a fault inside an appliance can give you a shock that seems to come from the power point.
No safety switch on that circuit Older boards
A safety switch (RCD) cuts the power fast if current leaks to earth, which greatly reduces the risk of serious injury. Many older boards have them on only some circuits, or none.
What kind of shock was it?
How it felt and when it happened helps us find the fault. Don't touch it again to check.
A tingle touching the switch
A buzz or tingle in your fingers when you touch a light switch, often an old metal plate or a cracked one, means voltage is getting where it should not be.
A shock as you plug in or unplug
A jolt as you push a plug in or pull it out can be a cracked plate, a damaged plug, or fingers touching a pin while it's partly in the socket.
A shock from an appliance
If you got it from the toaster, kettle or a metal lamp rather than the wall, the appliance or its earth may be faulty. Stop using it.
A sharp snap in dry weather
A sharp snap and a tiny spark when you touch a metal switch after walking on carpet is usually static. It happens on door handles too. A tingle that repeats every time isn't static.
Wet hands or a wet room
A shock in the bathroom, laundry or kitchen, or with wet hands, is more dangerous. Water lets current through your skin more easily.
Nothing tripped
If you felt a shock and no safety switch tripped, that circuit may not have one, or the shock was too small to trip it. Either way, it needs checking.
How we make it safe
We isolate it, find out why it was live, and fix the cause, not just the plate.
- 1
Isolate the circuit
Lachie switches off the circuit at the switchboard and proves it's dead before taking anything apart. If it's urgent, he'll talk you through switching it off at the board while he's on the way.
- 2
Find out why it was live
We check the plate, the terminals, the wiring and the earth connection at that fitting. Then we test the earth and the safety switch for that circuit at the board.
- 3
Replace and repair
We replace the damaged switch or power point, remake loose connections and repair the earth if it's faulty. You get the price before any work starts.
- 4
Test the safety switch and sign off
We test that the circuit's safety switch trips fast enough, check the earth, and show you what we found. You get a Certificate of Compliance for Electrical Work (CCEW) where the work needs one.
Replace the fitting, test the safety switches, or add more: your options side by side
Making the switch or power point safe comes first. What else is worth doing depends on what your board has.
A safety switch is the best protection you have against an electric shock. If your board doesn't have them on every circuit, Lachie will tell you, price it, and leave the choice to you.
What you can safely do now
Make sure everyone is safe first, then deal with the switch or power point.
Safe to do now
- If someone is still touching the switch or an appliance, don't touch them. Switch off at the main switch if it's safe to reach, then call 000.
- If anyone has been hurt, burnt or feels unwell after a shock, call 000.
- Stop using that switch or power point. Switch its circuit off at the switchboard, if the board is dry and safe to reach.
- Once the circuit is off, unplug the appliance if it's dry and undamaged, and don't use it until it's checked.
- Tape over the switch or power point so nobody uses it.
- Call Lachie on 0402 079 953.
Don't
- Don't touch it again to see if it still happens.
- Never touch anything wet, and never touch a switch or power point with wet hands.
- Don't take the plate off or try to tighten anything. That's licensed electrical work in NSW.
- Don't keep using the appliance you were holding until it has been checked.
Call straight away if
- Anyone is hurt or unwell after a shock: call 000.
- The tingle comes from a tap, the shower or a metal pipe: call Ausgrid on 13 13 88 first.
- More than one switch or power point is giving tingles, or the lights are dimming and flaring: call Ausgrid on 13 13 88, then us.
- There's a burning smell, sparks or scorch marks at the fitting. If there's smoke or fire, call 000 and never put water on it.
Questions people ask
Why did I get a shock from a light switch?
Usually a cracked plate, a loose wire touching metal behind it, or an old metal plate with a faulty earth. Static from carpet can also give a sharp snap, but a tingle that repeats isn't static. Stop using the switch and get it checked.
Is a small tingle from a power point dangerous?
Yes. A tingle means current is reaching you. With wet hands, or if the fault gets worse, it can be a serious shock. Switch the circuit off, stop using it and call.
Should I see a doctor after an electric shock?
If you're hurt, burnt or feel unwell, or have chest pain or a racing heart, call 000. Even if you feel fine, it's sensible to see a doctor after a shock from household power.
Why didn't my safety switch trip?
That circuit may not have a safety switch, the switch may not be working, or the shock didn't leak enough current to earth to trip it. We test every safety switch so you know where you stand.
Was it just static?
Maybe. A sharp snap and a tiny spark when you touch metal after walking on carpet, especially in dry weather, is static. It happens on door handles too. A tingle or buzz that repeats every time you touch the same switch isn't static.
Can you come tonight?
Yes. Lachie takes urgent calls from 4am to 9:30pm, 7 days. Call 0402 079 953, tell us what happened, and keep that circuit off at the switchboard while you wait. You get the price before any work starts.

Get a free quote from Lachie
Four quick details and Lachie will be in touch. Your quote is back within 24 hours, with no hidden fees.
- Free quotes. Back to you within 24 hours, in plain English, with no hidden fees.
- Upfront pricing. You know the cost before any work starts.
- 100% satisfaction guarantee. Not happy with the work? Lachie comes back and makes it right, free.
- Quality guarantee. Every job done to the Australian wiring rules (AS/NZS 3000), with parts that meet Australian standards, and tested before we leave.
Rather talk it through? Call Lachie on 0402 079 953