Air con tripping the power? We'll check the circuit and the unit's wiring
Often it's water in the outdoor isolator, a circuit too small for the unit, or a fault in the air con itself. Lachie tests each and fixes the electrical side.
5.0 from 24 Google reviewsUpfront pricesLicensed & insured

Offers on this job
- $0Call-out feeOn booked jobs, Monday to Friday, 7am to 5pm.
- $200 offSwitchboard upgradeOld fuses or no safety switches? Save on a new switchboard.
- $60 offYour first jobNew customers save on their first booked job.
The $0 call-out is for booked jobs: a time we have set together, with the work going ahead. It applies Monday to Friday, 7am to 5pm. After-hours emergency call-outs have a minimum charge of $349 + GST, and Lachie confirms it on the phone before he drives out.
Where an air con trips the power
Power runs from your switchboard, through an isolating switch beside the outdoor unit, to the air con. Which switch trips, and when, shows which part to test.
- The outdoor isolator
- The circuit and breaker at the switchboard
- The compressor starting
- The cable between the units
- The indoor unit
The outdoor isolator
Sun cracks its cover and seals, then rain gets in. If the safety switch trips after rain, this is the first place we look. A simple repair.
The circuit and breaker at the switchboard
Bigger units need their own circuit and breaker, sized to suit. If a breaker trips on hot days, or when the oven is on too, the circuit may be too small or shared.
The compressor starting
That thump outside is the compressor starting, with a rush of current. If the breaker trips right then, the circuit or the compressor is struggling. Faults inside the unit go to an air con technician.
The cable between the units
It runs through the wall and along the house. Sun, rodents and building work can damage it and make it leak power to earth.
The indoor unit
Turn the air con off with the remote before you reset anything. If the wiring tests fine, we give you the results to take to the installer or manufacturer.
What usually causes it: more detail on each cause
Air con faults fall into two groups: the power to the unit, which is an electrician's job, and the unit itself, which is for an air con technician.
Water in the outdoor isolator Most common
Every outdoor unit has an isolating switch beside it so it can be switched off for servicing. Years of sun crack the cover and seals, water gets in, and it trips the safety switch in wet weather. It's a common, simple repair.
A circuit too small for the unit Breaker trips
Smaller split systems often plug into an ordinary power point. Bigger units need their own circuit, with cable and a breaker sized to suit. When it's undersized, the breaker trips on hot days.
A loose or burnt connection
An air con draws heavy current for hours. A loose terminal at the switchboard, the isolator or the unit heats up and scorches, and can trip the breaker.
A fault inside the unit
A failing compressor, fan motor or circuit board can leak current or draw too much. That's for an air con technician, or the manufacturer if it's under warranty. We tell you if that's where the fault is.
Damaged cable between the units Less common
The cable from the indoor unit to the outdoor one runs through walls and along the house. Sun, rodents and building work can damage it.
A switchboard with no room left Older boards
Ceramic fuses, one safety switch for everything, or no spare space make it hard to give an air con its own protected circuit. That is when a board upgrade comes into it.
What trips, and when, tells us where to look
Check whether it's the safety switch or a circuit breaker that's gone. They point to different faults.
The safety switch trips after rain
Water has got into something outdoors, very often the isolating switch beside the outdoor unit. Sun cracks their covers and seals, and rain does the rest.
A breaker trips as the compressor starts
A thump outside, then the breaker goes. The compressor draws a rush of current as it starts. If the circuit is too small, or the compressor is struggling, it trips.
It trips after running a while on a hot day
That points to a circuit working near its limit, a loose connection heating up, or a unit working harder than it should.
It trips when the oven or kettle is on too
If the air con only trips when other things run, it's probably sharing a circuit, or the house is near its total load.
A new unit that trips from day one
A brand-new install that trips usually points to the wiring or the circuit it's on. Call the installer back first, since it's their work.
How we fix it
We check the power to the unit first, then tell you plainly if the unit itself is the fault.
- 1
Talk it through on the phone
Lachie asks which switch tripped, what the weather was doing and how old the unit is. A photo of the switchboard and the outdoor unit's label helps.
- 2
Check the circuit and the isolator
He isolates the air con circuit, opens the outdoor isolator and checks it for water, rust and burnt contacts. Then he tests the cable from the switchboard to the unit.
- 3
Measure what the unit draws
With the unit running, he measures its current against what the circuit and breaker are rated for. That shows whether the circuit is too small, or the unit is drawing more than it should.
- 4
Fix it, or point you to the right person
You get the price before any work starts. A wet isolator is replaced with a new weatherproof one, connections are remade, and an undersized circuit is upgraded. If the unit is faulty, you get our test results to take to the installer or manufacturer. You get a Certificate of Compliance for Electrical Work (CCEW) where the work needs one.
Fix the isolator, give it its own circuit, or upgrade the board: your options side by side
Most air con trips are fixed at the isolator or a connection. The circuit and board only come into it when they're the cause.
Refrigerant work needs a refrigerant handling licence, so faults inside the unit go to an air con technician. Most tripping is fixed without a new board.
What you can safely do now
These are safe for anyone. Inside the isolator, the unit or the switchboard is for a licensed electrician or air con technician.
Safe to do now
- Turn the air con off with the remote.
- Switch off the air con circuit at the switchboard if it's dry and safe to reach. It's often labelled air con or A/C.
- Reset the safety switch or breaker once, with the air con off, to get the rest of the house back. If it trips again, leave it off.
- Note the weather and what else was on, and take a photo of the switchboard.
- Keep kids and pets away from the outdoor unit and its isolator.
Don't
- Don't open the outdoor isolator or the unit's covers, even to dry them out.
- Don't turn the air con back on to see if it trips again.
- Don't touch the isolator or outdoor unit while it's wet.
Call straight away if
- There is a burning smell, smoke or scorch marks at the isolator, the unit or the switchboard. Smoke or fire: call 000, and never put water on it.
- You feel a tingle from the outdoor unit, a tap or anything metal. Keep everyone away and call Ausgrid on 13 13 88 first, then us.
- The safety switch will not stay on even with the air con circuit off.
Questions people ask
Why does my air conditioner trip the safety switch?
Most often water has got into the outdoor isolator or wiring, and current is leaking to earth, usually in or after rain. A fault inside the unit can do it too. We test the circuit and isolator first.
Why does the power trip when the aircon is on?
If a breaker trips, the circuit is likely too small for the unit or shared with other heavy appliances. If the main switch trips, the house may be near its limit. If it's the safety switch, it's a leak to earth. Each has a different fix.
Is it the air con or the wiring?
We test the wiring first: the circuit, the isolator and the cable to the unit. If they pass and the unit still trips it, the fault is in the air con, and that's for an air con technician or the manufacturer. You get the results to show them.
Does an air conditioner need its own circuit?
Larger units do, and the installation manual says what each model needs. Smaller split systems often plug into a power point, but on a shared circuit they can trip it on hot days. A dedicated circuit stops that.
Do I need a switchboard upgrade for air con?
Not always. If your board has safety switches and spare room, we can add the circuit. If it has ceramic fuses, no safety switches or no space, an upgrade may be needed. Lachie tells you straight, and you decide.
Can you come today?
Often, yes. Lachie works Monday to Friday, 7am to 5pm, and takes urgent calls from 4am to 9:30pm, 7 days. Leave the air con circuit off until he gets there. Call 0402 079 953 and you get the price before any work starts.

Get a free quote from Lachie
Four quick details and Lachie will be in touch. Your quote is back within 24 hours, with no hidden fees.
- Free quotes. Back to you within 24 hours, in plain English, with no hidden fees.
- Upfront pricing. You know the cost before any work starts.
- 100% satisfaction guarantee. Not happy with the work? Lachie comes back and makes it right, free.
- Quality guarantee. Every job done to the Australian wiring rules (AS/NZS 3000), with parts that meet Australian standards, and tested before we leave.
Rather talk it through? Call Lachie on 0402 079 953