New induction cooktop tripping the power? Your circuit may be too small, we'll check it
Many induction cooktops draw more power than the one they replaced. If the cable or breaker is too small, it trips. Lachie checks the circuit and upgrades it if needed.
5.0 from 24 Google reviewsUpfront pricesLicensed & insured

Offers on this job
- $0Call-out feeOn booked jobs, Monday to Friday, 7am to 5pm.
- $200 offSwitchboard upgradeOld fuses or no safety switches? Save on a new switchboard.
- $60 offYour first jobNew customers save on their first booked job.
The $0 call-out is for booked jobs: a time we have set together, with the work going ahead. It applies Monday to Friday, 7am to 5pm. After-hours emergency call-outs have a minimum charge of $349 + GST, and Lachie confirms it on the phone before he drives out.
Why an induction cooktop trips the power
Most induction cooktops draw more than the cooktop they replaced. The cable, the connection under the bench and the breaker all have to suit it.
- Several zones on high
- The terminal block under the bench
- The cable from the switchboard
- The circuit breaker that tripped
- The safety switch
Several zones on high
One zone is fine, but two or three on high or boost and it trips. That's the classic sign of a circuit too small for the cooktop.
The terminal block under the bench
Links on the terminal block set the cooktop up for your supply. If they don't match, or a terminal is loose, it can trip or overheat.
The cable from the switchboard
The manual says what cable the cooktop needs. A kitchen that had gas may have no cooktop circuit at all, and older ones often share with the oven.
The circuit breaker that tripped
It protects the cable. If the cooktop draws more than the circuit can carry, it trips, as it should. The fix is the right circuit, not a bigger breaker.
The safety switch
If the safety switch trips instead, power is leaking to earth: a fault in the cooktop or wiring, or an older safety switch that reacts to the cooktop's electronics.
What usually causes it: more detail on each cause
With a new induction cooktop, the circuit is the usual suspect. The cooktop itself is less often the fault.
A circuit too small for the cooktop Most common
The installation manual says what cable and breaker a cooktop needs. Many full-size induction cooktops need a bigger circuit than an old electric cooktop, and a kitchen that had gas may have no cooktop circuit at all. Too small, and the breaker trips under load, as it should.
Oven and cooktop sharing one circuit
Older kitchens often run the oven and cooktop from one circuit. Swap in induction and use both at once, and the total can be more than the breaker allows.
Connected wrong at the terminal block New installs
Many induction cooktops can be connected to suit different supplies, using links on the terminal block. If the links don't match your supply, or a terminal is loose, it can trip or overheat.
A fault in the new cooktop
New appliances can arrive faulty or be damaged in transit. If the circuit tests fine and the cooktop still leaks current or trips, that's a warranty claim with the manufacturer.
An older safety switch Older boards
Induction cooktops are full of electronics, and some older safety switches react to them. The fix can be a newer type of safety switch on that circuit, if the board can take it.
Your whole supply near its limit Less common
Add induction to air con, an oven, electric hot water and an EV charger, and some homes run short. A supply upgrade involves Ausgrid and the service fuse, which is Ausgrid or Level 2 accredited work.
What trips, and when, tells us the cause
Check whether the circuit breaker or the safety switch has gone. With a new induction cooktop, it's usually the breaker.
The breaker trips with several zones on high
One zone is fine, but turn on two or three, or use boost, and the breaker goes. That's the classic sign of a circuit too small for the cooktop.
It trips when the oven's on too
Many kitchens have the oven and cooktop on one circuit. An induction cooktop plus the oven can draw more than that circuit was built for.
It trips the moment you switch it on
If it goes before you've turned up a zone, think wiring: a connection made wrong, a loose terminal or a fault in the cooktop. Leave it off.
The safety switch trips, not the breaker
That's current leaking to earth. It can be a fault in the cooktop or its wiring, or an older safety switch not suited to the cooktop's electronics.
The main switch trips
If the whole house goes off when you cook, the cooktop on top of air con, the oven and hot water may be more than your main switch or supply can carry.
How we fix it
We check the cooktop's requirements against your circuit, then fix whatever doesn't match.
- 1
Check the cooktop's requirements
On the phone, Lachie asks for the make and model and a photo of your switchboard. The installation manual says what circuit the cooktop needs, so he can often tell you the likely problem before he arrives.
- 2
Check and test the circuit
At the switchboard he checks the breaker and cable against the manual, and whether the oven shares them. He tests the cable with an insulation resistance tester and measures what the cooktop draws.
- 3
Check the connection at the cooktop
With the circuit isolated and proven dead, he checks the cooktop's terminal block: the links, the terminals and the cable entry. Anything loose or set up wrong is fixed.
- 4
Upgrade the circuit, if it needs it
You get the price before any work starts. That might be a bigger cable and breaker, a separate circuit for the oven, or a newer safety switch. If the switchboard has no room, we explain why and price that too. You get a Certificate of Compliance for Electrical Work (CCEW) where the work needs one.
Fix the connection, run a new circuit, or upgrade the board: your options side by side
The cooktop's manual and a few tests tell us which you need.
Some induction cooktops can be set to draw less, to suit a smaller circuit, though cooking on full is then slower. We'll tell you if yours can, so you can weigh it against a new circuit.
What you can safely do now
These are safe for anyone. The cooktop's connection and the switchboard are a licensed electrician's job.
Safe to do now
- Turn the cooktop off at its controls.
- Switch off the cooktop circuit at the switchboard if the board is dry and safe to reach. It may be labelled cooktop, hotplates, range or stove.
- Reset the breaker once with the cooktop off. If it trips again, leave it off.
- Find the installation manual, or note the make and model, and take a photo of the switchboard.
- If it was just installed, call the installer first. It's their work.
Don't
- Don't keep resetting the breaker and trying again.
- Don't lift the cooktop out of the bench or open its connection box.
- Don't plug a full-size cooktop into a power point or extension lead to get it going.
- Don't have a bigger breaker fitted without checking the cable. The breaker protects the cable, and a bigger one can let it overheat.
Call straight away if
- There's a burning smell, smoke or scorch marks at the cooktop, its wall switch or the switchboard. Smoke or fire: call 000, and never put water on it.
- You feel a tingle from the cooktop, the sink or a tap. Keep everyone away and call Ausgrid on 13 13 88 first, then us.
- The main switch trips and the whole house goes off when you cook.
Questions people ask
Why does my new induction cooktop keep tripping?
Most often the circuit is too small for it. Many induction cooktops need a bigger cable and breaker than the cooktop they replaced, and some share a circuit with the oven. Less often it is the connection, a faulty cooktop or an older safety switch.
What size circuit does an induction cooktop need?
It depends on the model, so check the installation manual. Full-size cooktops usually need their own circuit, sized to their rating. Plug-in models are made to suit a power point. We match the cable and breaker to what the manual asks for.
Can I just put in a bigger breaker?
Not on its own. The breaker protects the cable. If the cable is too small for a bigger breaker, it can overheat before the breaker trips. If the circuit needs more capacity, the cable and breaker are upgraded together.
Do I need a switchboard upgrade for an induction cooktop?
Not always. If your board has room and safety switches, we can usually add or upgrade the circuit. If it has ceramic fuses, no room or no safety switches, an upgrade may be needed. Lachie tells you straight, and you decide.
My cooktop was just installed. Who do I call?
The installer first, since it's their work, and the manufacturer if the cooktop seems faulty. If you can't get them back, or want a second opinion, we'll test the circuit and the connection and give you the results.
Can you come today?
Often, yes. Lachie works Monday to Friday, 7am to 5pm, and takes urgent calls from 4am to 9:30pm, 7 days. Have the make and model handy when you call 0402 079 953, and you get the price before any work starts.

Get a free quote from Lachie
Four quick details and Lachie will be in touch. Your quote is back within 24 hours, with no hidden fees.
- Free quotes. Back to you within 24 hours, in plain English, with no hidden fees.
- Upfront pricing. You know the cost before any work starts.
- 100% satisfaction guarantee. Not happy with the work? Lachie comes back and makes it right, free.
- Quality guarantee. Every job done to the Australian wiring rules (AS/NZS 3000), with parts that meet Australian standards, and tested before we leave.