No power to the garage or shed? We'll trace the fault and get it back on
A dead garage or shed usually means a tripped safety switch, a faulty fridge or tool, or a damaged cable from the house. We trace it and fix it.
5.0 from 24 Google reviewsUpfront pricesLicensed & insured

Offers on this job
- $0Call-out feeOn booked jobs, Monday to Friday, 7am to 5pm.
- $60 offYour first jobNew customers save on their first booked job.
The $0 call-out is for booked jobs: a time we have set together, with the work going ahead. It applies Monday to Friday, 7am to 5pm. After-hours emergency call-outs have a minimum charge of $349 + GST, and Lachie confirms it on the phone before he drives out.
How power gets to your garage or shed, and where it stops
A detached garage or shed is fed by its own cable from the house switchboard, usually underground, often to a small switchboard in the shed.
- The switch at the house
- The cable to the garage
- The sub-board in the garage
- An old fridge or power tool
- Water in an outdoor fitting
The switch at the house
The breaker or safety switch for the garage at your main board. It often shares a safety switch with outdoor lights and power points. Reset it once.
The cable to the garage
Usually underground. Digging, fence posts, tree roots and water in old conduit can damage it. We find the fault by testing before anything is dug up.
The sub-board in the garage
Many sheds have their own small switchboard. If its breaker or safety switch has tripped, the board in the house can look fine.
An old fridge or power tool
Old garage fridges, freezers, compressors and worn extension leads leak power and trip the safety switch. Unplug it and leave it unplugged until it's tested.
Water in an outdoor fitting
If it trips when it rains, water is getting into an outdoor light, a power point or the cable to the shed.
What usually causes it: more detail on each cause
Garages and sheds are hard on electrics: damp, dust, heavy tools and old fridges. These are the usual culprits.
A tripped safety switch Most common
Garage circuits often share a safety switch with outdoor lights and power points. Water outside, or one faulty appliance in the garage, trips the lot, and sometimes part of the house too.
An old fridge, freezer or power tool
Second fridges and freezers in garages are often old, and their motors leak current as they age. Grinders, compressors and worn extension leads do the same.
A tripped sub-board in the shed
Detached sheds and garages often have their own small switchboard. If the breaker or safety switch there has tripped, the main board in the house can look fine.
A damaged underground cable
The cable to a detached shed usually runs underground. Digging, fence posts, tree roots and water in old conduit joints can damage it. We find the fault by testing before anything is dug up.
Too much on one power point Workshops
Welders, compressors and heaters can pull more than a standard 10 amp power point and circuit are built for. That trips the breaker or overheats the power point.
Old or makeshift wiring Older sheds
Leads run from the house, unprotected cable and old fittings are common in older sheds. They fail more often and aren't a safe permanent supply.
What the garage is telling you
Check what's dead in the garage and what still works in the house. It narrows the fault down quickly.
Power points and lights both dead
The whole garage supply is off: a tripped switch at the main board, a tripped sub-board in the shed, or a damaged cable feeding it.
Only the power points are dead
One power circuit has tripped or a connection has failed. Garage power points often share a safety switch with outdoor ones.
The door motor stopped after a storm
The safety switch feeding it may have tripped, or a surge has damaged the motor itself. We check the power reaching it first.
It trips when the fridge or a tool starts
A second fridge, freezer, compressor or power tool is the likely cause. Unplug it and leave it unplugged until it's tested.
It trips when it rains
Water is getting into an outdoor power point, a light, the cable to a detached shed, or a fitting under a leaking roof.
It stopped after digging or fencing
The underground cable to a detached garage or shed may have been hit by a spade, post-hole digger or excavator.
How we trace it and get it back on
We start at the main switchboard and follow the supply out to the garage, so we find the break rather than guess.
- 1
Talk it through
Lachie asks what is dead, what was running, and whether it rained, someone dug nearby or there was a storm. A photo of your main board, and the shed board if there is one, helps.
- 2
Test from the main board
He checks the garage circuit at the main board and any sub-board in the shed, then tests the cable between them for damage and leaks to earth.
- 3
Find the faulty part
Appliances are tested one at a time, and the power points, lights and the door motor's power point are checked for water, dust and loose connections.
- 4
Repair, test, switch on
We replace the faulty power point, fitting or section of cable, test the circuit and its safety switch, and switch it back on. You get a Certificate of Compliance for Electrical Work (CCEW) where the work needs one.
Repair the fault, replace the cable, or upgrade the shed power: your options side by side
Most dead garages are one repair. If the supply to a shed is old or too small, it's worth fixing properly.
If the garage door motor itself is faulty, that's a job for a garage door technician. We check the power reaching it first, so you know who to call. You get the price before any work starts.
What you can safely do now
These are safe for anyone. Anything inside a switchboard, power point, fitting or door motor is a licensed electrician's job.
Safe to do now
- Unplug everything in the garage or shed, if it's dry and safe to touch.
- Check the main switchboard, and the shed board if there is one, if they are dry and safe to reach. Reset a tripped safety switch or breaker once.
- If it trips again, leave it off.
- Keep the garage fridge and freezer closed.
- Note what was running and whether it rained, and take photos of the boards.
- Keep kids and pets away from anything wet or damaged.
Don't
- Don't run an extension lead from the house as a fix. Leads aren't built for permanent use and can overheat.
- Don't dig near the shed cable, or pull at it to find the fault.
- Don't open power points, the door motor or either switchboard cover.
- Don't keep using a fridge, tool or lead you think is faulty.
Call straight away if
- There's a burning smell, buzzing or scorch marks at a power point, the door motor or a board. If there's smoke or fire, call 000 and never put water on it.
- A cable has been hit by digging. Keep everyone clear, and switch off at the main switch if it's dry and safe to reach.
- Water is getting into the garage near power points, lights or the board.
- You feel a tingle from the roller door, a tool or anything metal. Keep everyone clear. If it is a tap or the shower, call Ausgrid on 13 13 88 first.
Questions people ask
Why is there no power to my garage?
Usually a tripped safety switch, often set off by an old garage fridge, a tool or water in an outdoor fitting. If nothing's tripped, a connection or the cable from the house has failed. Check your boards, reset once, then call.
Why did my garage door stop working after a storm?
Either the safety switch feeding it tripped, or a surge damaged the motor. Check the board and reset once. If there's power at the motor and it still won't run, it's a job for a garage door technician.
How do I open my garage door with no power?
Most automatic doors have a manual release, usually a cord hanging from the motor rail. Follow the door maker's instructions. If the door is heavy or stuck, don't force it. Call a garage door technician.
Does my shed have its own switchboard?
Many detached sheds and garages do: a small board with a breaker or safety switch, often near the door. If it has tripped, the house board can look fine. Reset it once if it's dry and safe to reach.
Can I run power to my shed with an extension lead?
Not as a permanent supply. Leads aren't built to be left run out, buried or exposed to the weather, and they can overheat under heavy loads. A proper circuit to the shed, with safety switch protection, is licensed work.
Can you come today?
Often, yes. Lachie works Monday to Friday, 7am to 5pm, and takes urgent calls from 4am to 9:30pm, 7 days if there's a burning smell or a damaged cable. Call 0402 079 953 for a time. You get the price before any work starts.

Get a free quote from Lachie
Four quick details and Lachie will be in touch. Your quote is back within 24 hours, with no hidden fees.
- Free quotes. Back to you within 24 hours, in plain English, with no hidden fees.
- Upfront pricing. You know the cost before any work starts.
- 100% satisfaction guarantee. Not happy with the work? Lachie comes back and makes it right, free.
- Quality guarantee. Every job done to the Australian wiring rules (AS/NZS 3000), with parts that meet Australian standards, and tested before we leave.
Rather talk it through? Call Lachie on 0402 079 953