Often fixed the same day
Power out in one room but nothing's tripped? We'll trace the fault and fix it
When one room goes dead and nothing has tripped, a connection has usually failed along that circuit. Lachie tests from the board, finds the break and repairs it.
5.0 from 24 Google reviewsUpfront pricesLicensed & insured

Offers on this job
- $0Call-out feeOn booked jobs, Monday to Friday, 7am to 5pm.
- $60 offYour first jobNew customers save on their first booked job.
The $0 call-out is for booked jobs: a time we have set together, with the work going ahead. It applies Monday to Friday, 7am to 5pm. After-hours emergency call-outs have a minimum charge of $349 + GST, and Lachie confirms it on the phone before he drives out.
Why one room can go dark with nothing tripped
Power runs from your switchboard along each circuit, from one power point or light to the next. If a connection fails partway along, everything after it goes dead, and the board still looks fine.
- The street supply (Ausgrid's)
- The main switch or a safety switch
- One circuit off: only some rooms out
- A fault in the wiring
- The service fuse and mains
The street supply (Ausgrid's)
Not the cause here. If the rest of the house works, the supply from the street is fine. Only call Ausgrid if lights flare and dim or a tap gives a tingle.
The main switch or a safety switch
Look closely. A tripped safety switch can sit in the middle position and look on at a glance. If you find one, reset it once.
One circuit off: only some rooms out
A circuit breaker can fail inside without its lever moving. It looks on, but no power gets through. A quick test at the board shows it.
A fault in the wiring
The most likely cause. A loose or burnt connection at a power point, light switch or junction box in the roof cuts off everything after it.
The service fuse and mains
Not usually involved when one room is out. In a three-phase home, though, losing one phase can take out a few rooms, so we check it.
What usually causes it: more detail on each cause
If nothing has tripped, the switchboard hasn't cut the power. Something along the circuit has.
A loose or burnt connection Most common
Power points and switches are wired one after another. Terminals loosen as they heat and cool over the years, and one failed joint cuts off everything after it. There are often heat marks behind the plate.
A failed junction box in the roof
Lighting circuits, and some power circuits, join in junction boxes in the roof space. These loosen, overheat or get knocked during other work, and they're out of sight.
A cable damaged by a screw, nail or rodent
A fixing through a wall cable, or rats and possums chewing cables in the roof, can break a circuit without tripping it. We find these by testing first, so walls only get opened where needed.
A breaker that has failed inside Less common
Circuit breakers can fail without moving their lever, so the board looks normal while the circuit gets nothing. Testing at the board shows it in minutes.
Old wiring breaking down Older homes
Rubber-insulated or very old cable goes brittle, and joints in it crumble when disturbed. If a circuit keeps failing, rewiring that circuit can be the lasting fix.
What the dead room tells us
Walk through the house and note exactly what works and what doesn't. It narrows the search a lot.
Only the power points are out
One power circuit has stopped partway. The dead power points often carry on into the next room, and so does the fault.
Only the lights are out
A lighting circuit has failed at a switch, a fitting or a junction box in the roof.
Lights and power points are both out
They're usually on separate circuits, so check for a half-tripped safety switch first. If nothing's off, it can be a lost phase in a three-phase home.
It flickered or crackled before it died
A loose connection usually works on and off before it fails for good. A crackle or a warm plate are warning signs.
It went after work in the house
A new shelf, picture hook, downlight or renovation can put a screw through a cable or disturb an old connection.
How we trace it and fix it
We test, then follow the circuit from the board to the break. No guessing, and no holes where we don't need them.
- 1
Talk it through
Lachie asks which power points and lights are out, and what happened just before. A photo of your switchboard helps him come prepared.
- 2
Test at the switchboard
He checks each safety switch and breaker is really passing power, and finds which circuit the room is on. That rules the board in or out straight away.
- 3
Follow the circuit to the break
Starting at the last working power point or light, he isolates the circuit, proves it's dead and checks each connection, including junction boxes in the roof, until he finds the failed one.
- 4
Repair, test and show you
Burnt connections are cut back and remade, and damaged power points, switches or cable are replaced. We test the circuit, switch it back on and show you what failed. You get a Certificate of Compliance for Electrical Work (CCEW) where the work needs one.
Repair the connection, replace the cable, or rewire the circuit: your options side by side
Most dead rooms are fixed by remaking one connection. If the wiring itself is the problem, these are your choices.
A dead room isn't a reason on its own to upgrade the switchboard. We tell you what we find and price it before any work starts, and you decide.
What you can safely do now
These are safe for anyone. Anything behind a power point plate, a switch or the switchboard cover is a licensed electrician's job.
Safe to do now
- Look closely at every safety switch and breaker. If one is off or sitting in the middle, reset it once, if the board is dry and safe to reach.
- Check the power points in that room are switched on, and try a lamp you know works.
- Unplug appliances in the dead room, if they're dry and safe to touch, so nothing comes back on unattended.
- Note which power points and lights are out, and take a photo of the switchboard.
- If a plate feels warm or you smell burning, switch that circuit off at the board, or use the main switch if you can't tell which it is.
Don't
- Don't take power point plates or switch covers off, or try tightening anything.
- Don't keep flicking breakers on and off to see what happens.
- Don't run extension leads across the house as a fix. The fault is still there and may be getting hot.
- Don't touch a power point or switch that's warm, discoloured or crackling.
Call straight away if
- You can smell burning or hot plastic, or a power point or switch feels warm.
- You can hear crackling or buzzing in a wall or ceiling.
- The dead room has a fridge, freezer or medical equipment you need running.
- You feel a tingle from a tap or appliance. Keep everyone clear and call Ausgrid on 13 13 88 first.
Questions people ask
Why is there no power in one room but the breaker hasn't tripped?
A connection has usually failed partway along the circuit, at a power point, a switch or a junction box in the roof. Breakers only trip on overloads and shorts, so a broken connection can stop the power without tripping anything.
Can a circuit breaker go bad without tripping?
Yes. A breaker can fail inside and stop passing power while the lever still shows on. It's not common, but a quick test at the board shows it. Don't open or swap breakers yourself.
Is a dead room dangerous?
It can be. The connection that failed may have overheated first. If you smell burning or a plate feels warm, switch that circuit off at the board and call. If it's just dead and cool, it's a today job, not an emergency.
Why did only some power points in my room stop working?
Power points are wired one after another. If a connection fails at one, the ones after it go dead and the ones before keep working. The fault is usually at the last working power point or the first dead one.
Do I need my house rewired?
Not usually. Most dead rooms are one failed connection. If we find old rubber-insulated cable or several failing joints, we'll show you and price rewiring that circuit. The choice is yours.
Can you come today?
Often, yes. Lachie works Monday to Friday, 7am to 5pm, and takes urgent calls from 4am to 9:30pm, 7 days if there's heat or a burning smell. Call 0402 079 953 and you'll get a time, and the price before any work starts.

Get a free quote from Lachie
Four quick details and Lachie will be in touch. Your quote is back within 24 hours, with no hidden fees.
- Free quotes. Back to you within 24 hours, in plain English, with no hidden fees.
- Upfront pricing. You know the cost before any work starts.
- 100% satisfaction guarantee. Not happy with the work? Lachie comes back and makes it right, free.
- Quality guarantee. Every job done to the Australian wiring rules (AS/NZS 3000), with parts that meet Australian standards, and tested before we leave.
Rather talk it through? Call Lachie on 0402 079 953